Behavior of FRP‐Reinforced Concrete Columns Subjected to Combined Axial Compression and Lateral Loading
Mohammad Kazem Sharbatdar, Murat Saatcioglu
Key points
From the paper's conclusion- These results confirm that plane‐section analysis remains applicable for evaluating the behavior of concrete members reinforced with FRP bars.
Abstract
This study assessed the structural properties of carbon fiber‐reinforced polymer (CFRP)‐reinforced concrete columns through large‐scale experimental testing. Ten columns, representing a segment of a first‐story building column from the footing to the point of inflection, were tested under constant axial load to simulate seismic loading conditions. Test parameters included the arrangement of longitudinal bars, spacing of transverse reinforcement, specimen length, and level of constant axial load. Columns with higher CFRP bar content, reduced CFRP grid spacing, and higher axial compression levels exhibited ductile behavior, developing inelastic displacement with minimal strength loss before failure. The predominant failure mode was governed by concrete crushing, which preceded rupture of the CFRP reinforcement in tension. In compression, CFRP bars failed through an instability (buckling) mechanism distinct from that of steel reinforcing bars: unlike steel, which undergoes plastic deformation, CFRP bars exhibited significant bending prior to reaching instability, without any capacity for plastic yielding. All columns sustained applied drift ratios with no or only limited loss of lateral strength, exceeding the 2% and 2.5% drift limits specified for earthquake‐resistant columns in the National Building Code of Canada. Hysteretic behavior revealed stiffness degradation resulting from cracking and inelastic concrete crushing; however, the hysteresis loops of CFRP‐reinforced members differed markedly from those of steel‐reinforced columns. Displacement ductility ratios ranged from 1.9 to 3.4 depending on the test parameters, while drift ratios ranged from a maximum of 2% at peak lateral strength to an ultimate value of 4.55% at failure. To further evaluate the behavior of CFRP‐reinforced concrete members, a confined concrete model originally developed from tests on steel‐reinforced columns under concentric loading was applied. Analytical moment‐curvature and moment‐axial force interaction relationships were computed and compared against experimental results, with the confined concrete model underestimating experimental values by 5%–28%. These results confirm that plane‐section analysis remains applicable for evaluating the behavior of concrete members reinforced with FRP bars.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Compression-Shear Hysteretic Performance of Circular Section Members Strengthened with CFRP-Wrapped Steel Tube Confined Concrete.Materials (Basel, Switzerland) · 2026
- Structural behavior of HPC columns reinforced with CFRP bars under axial loading.Scientific reports · 2026
- Axial Compressive Behaviour of Intermediate-Length Concrete-Filled Steel Tubular Columns with Different CFRP Wrapping ConfigurationsBuildings · 2026
- Behaviour of Pre-Damaged Concrete Columns with Different Geometries Retrofitted by using CFRPIOP Conference Series: Earth and Environmental Science · 2026
- CFRP-Confined Pre-Damaged Recycled Aggregate Concrete Square Columns Under Axial CompressionApplied Sciences · 2026
- Experimental study of concrete-encased composite columns with GFRP-steel tubes filled with sea-sand concrete under cyclic loadingEngineering Structures · 2026