SPLAT: An Event-Specific System Response Model for Continuous-Domain List-Mode TOF PET.
Ronglong Fang, Andrzej Krol, Yuesheng Xu, Eric S Harmon, Michael O Thompson, Wei Zheng, C Ross Schmidtlein
Key points
From the paper's conclusion- We introduce Spatial Probability Localization and Transformation (SPLAT), a continuous-domain, event-specific projection model for time-of-flight (TOF) list-mode PET.
Abstract
Modern position-sensitive PET detectors provide continuous estimates of photon interaction position and event-specific timing, energy, and depth-of-interaction (DOI) information. We introduce Spatial Probability Localization and Transformation (SPLAT), a continuous-domain, event-specific projection model for time-of-flight (TOF) list-mode PET. Each coincidence is represented by a three-dimensional spatial response kernel incorporated into consistent forward and adjoint operators without detector-coordinate binning. While supporting general response distributions, we develop an anisotropic Gaussian implementation whose center is determined by measured interaction positions and TOF difference, and whose full covariance follows from propagating measurement uncertainties through event geometry. The model accounts for DOI, photon non-collinearity, and energy-dependent, correlated, and depth-dependent detector responses. Using GATE Monte Carlo simulations with known annihilation positions, we compare continuous and virtually segmented representations of identical accepted coincidences. Event-localization diagnostics and point-source and brain-phantom reconstructions assess model accuracy and image formation. The Gaussian formulation also yields information-equivalent count gain, an approximate measure of relative spatial information accounting for localization uncertainty and detection efficiency. Results support the value of event-specific modeling, particularly measured DOI, while an optimized GPU implementation demonstrates computational feasibility. SPLAT provides a flexible framework for incorporating detailed detector measurements directly into PET reconstruction.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Detector-side neural timing calibration for TOF-PET from coincidence supervisionPhysics in Medicine & Biology · 2026
- Single-Scattered events Imaging in ToF-PET via Machine Learning-Based Classification.Biomedical physics & engineering express · 2026
- Impact of depth-of-interaction and spatially-variant point-spread-function model on the performance of ultra-high resolution brain PET.Physics in medicine and biology · 2026
- PhysiCal-PET: Physics-driven neural networks for the rapid position Calibration of PET ScannersarXiv · 2026
- A Source-Traced PET/CT Scanner Performance Database (2004-2024): The Sphere-Size Dependence of Time-of-Flight Contrast Recovery.Diagnostics (Basel, Switzerland) · 2026
- Attenuation corrected activity reconstruction for listmode TOF-PET data.ArXiv · 2026