Attenuation corrected activity reconstruction for listmode TOF-PET data.
Ahmadreza Rezaei, Suleman Surti, Samuel Matej, Joel S Karp, Johan Nuyts
Key points
From the paper's conclusion- With an "optimal" histogramming of the measurements, the attenuation corrected activity distributions from TOF emission data only are comparable to the gold-standard in PET/CT.
Abstract
Time-of-flight (TOF) positron emission tomography (PET) emission data allow joint estimation of the activity and attenuation images. The methods proposed so far rely on reconstructions from TOF histograms of the measurements. However, with the rapid data increase of total-body (TB) scanners and the ever improving TOF and intrinsic resolutions, more memory and computation efficient techniques for joint reconstruction need to be developed. In this work, a modified version of the maximum likelihood activity and attenuation correction factors algorithm (MLACF) is presented, that jointly estimates the activity image together with the attenuation factors (AFs) from listmode emission data. The method does not require TOF histogramming of the data, however it still relies on a coarsely sampled (i.e. mashed) non-TOF histogram of the emission data. The activity distribution is subsequently quantified by reconstructing and enforcing known expected tissue attenuation on an attenuation reconstruction from the estimated AF values. The algorithm is evaluated using 3D simulations as well as clinical TOF-PET measurements of a patient scan and compared to reference reconstructions. As could be expected, we find the reconstruction accuracies improve with an "optimal" histogramming of the TOF emission data, increasing the signal to noise ratio of the data used for joint estimation. With an "optimal" histogramming of the measurements, the attenuation corrected activity distributions from TOF emission data only are comparable to the gold-standard in PET/CT.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Attenuation Pre-Correction in Iterative PET Image Reconstruction: What is the Statistical Cost?IEEE transactions on radiation and plasma medical sciences · 2026
- Single-Scattered events Imaging in ToF-PET via Machine Learning-Based Classification.Biomedical physics & engineering express · 2026
- A Source-Traced PET/CT Scanner Performance Database (2004-2024): The Sphere-Size Dependence of Time-of-Flight Contrast Recovery.Diagnostics (Basel, Switzerland) · 2026
- Kinematic Total-Body PET Video Reconstruction via Hierarchical List-Mode EM and Validation-Adaptive Space-Time RegularisationarXiv · 2026
- SPLAT: An Event-Specific System Response Model for Continuous-Domain List-Mode TOF PET.ArXiv · 2026
- Detector-side neural timing calibration for TOF-PET from coincidence supervisionPhysics in Medicine & Biology · 2026