Patient-specific Modeling of the Tricuspid Valve from 3D Transesophageal Echocardiography
Davide Tondi (Department of Electronics, Information, Bioengineering, Politecnico di Milano, Milan, Italy), Vijay K. Dubey (Walker Department of Mechanical Engineering, The University of Texas at Austin,
Key points
From the paper's conclusion- We also assessed inter-observer segmentation variability and sensitivity to chordal insertion density, leaflet stiffness, leaflet thickness, and chordal size and material properties.
Abstract
Purpose: Image-based patient-specific simulations of the tricuspid valve (TV) could support repair planning. However, clinical images incompletely resolve the chordal anatomy and cannot directly determine tissue properties, which hinders the development of such models. We developed and evaluated a framework that simulates the TV from clinical images and addresses these limitations using measurements on explanted human valves. Methods: We reconstructed ten functionally competent human TVs from 3D transesophageal echocardiography. Following manual segmentation, we automatically built finite element models with synthetic chordae and with leaflet thickness, chordal insertion density, and tissue properties informed by ex vivo human measurements. Next, we used shape matching and force-based chordal-length adjustment to simulate valve closure. We also assessed inter-observer segmentation variability and sensitivity to chordal insertion density, leaflet stiffness, leaflet thickness, and chordal size and material properties. Results: Per-valve median geometric errors were 0.61-1.13 mm relative to the morphed references and 0.55-0.95 mm relative to the image-derived surfaces. Coaptation covered 20-42% of the leaflet area, and median leaflet stresses ranged from 7.6 to 16.9 kPa. Inter-observer variability in segmentation most strongly affected coaptation area. Of the population-based inputs, insertion density and leaflet stiffness most affected geometric error. Thickness primarily affected stress, whereas chordal size and material properties had limited effects. Conclusion: Clinical echocardiography, supplemented with ex vivo human tissue data, enabled patient-specific simulation of ten human TVs. This framework provides a foundation for investigating valve mechanics and developing repair-planning tools, while sensitivity analyses identify priorities for model refinement and uncertainty assessment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- No Strings Attached: Predicting Tricuspid Valve Deformation Without In Vivo Chordal Geometry.bioRxiv : the preprint server for biology · 2026
- Experimental Bench Validation of a Computational Fluid-Structure Interaction Model of Transcatheter Aortic Valve DynamicsarXiv · 2026
- Systematic Transesophageal Echocardiographic Identification of Tricuspid Valve Commissures and Subvalvular Apparatus.European heart journal. Cardiovascular Imaging · 2026
- Unlocking 360° multiplane transoesophageal echocardiography for transseptal puncture guidance in mitral transcatheter edge-to-edge repairEuropean Heart Journal · 2026
- Fully coupled patient-specific fluid-structure interaction modeling of post-TAVI hemodynamics compared with echocardiographic measurements.Biomechanics and modeling in mechanobiology · 2026
- Reconstruction of Left Ventricle Geometry for Finite Element Analysis Using 2D EchocardiographyComputation · 2026