No Strings Attached: Predicting Tricuspid Valve Deformation Without In Vivo Chordal Geometry.
Mrudang Mathur, Collin E Haese, Vijay K Dubey, Sumedh Seetharam, William D Meador, Tomasz Jazwiec, Natalie T Simonian, Michael S Sacks,
Key points
From the paper's conclusion- These results demonstrate that anatomically informed shape matching coupled with stress-based chordal calibration can reproduce tricuspid valve closure without explicit subject-specific chordal geometry.
Abstract
Predictive biomechanical models of the tricuspid valve require accurate representation of the chordae tendineae, yet subject-specific chordal geometry is difficult to reconstruct from non-invasive imaging. Here, we adopt a framework for generating functionally equivalent synthetic chordae without prior knowledge of in vivo chordal attachments. To this end, we first adapt an anatomy-informed hyperelastic shape-matching method that establishes correspondence between end-diastolic and end-systolic leaflet configurations using chordal-mimicking forces, a rigid contact template, and a Gaussian-smoothed locally corrective pressure field. We then generate synthetic chordal insertion sites using zone-based rejection sampling and calibrate the unloaded length of each chord by combining reaction forces with the chordal stress-stretch relationship. The framework was evaluated using Texas TriValve 1.1, a high-fidelity finite element model of a human tricuspid valve validated against beating-heart echocardiography. We found that shape matching reproduced the target end-systolic geometry with a mean inter-surface distance of 0.29 ± 0.35 mm. Moreover, synthetic chordal insertions faithfully reproduce end-systolic leaflet deformations. We subsequently examined synthetic chordal configurations containing 202, 225, and 450 insertions, informed by measurements from eight explanted human tricuspid valves. Here, increasing insertion number reduced mean inter-surface distance from 0.63 ± 0.52 mm to 0.49 ± 0.44 mm and reduced contact area errors from 3.52% to 0.59%. Across all configurations, mean maximum principal stretch errors in leaflet belly regions remained below 2.4%, while areal strain errors ranged from 0.34% to 10.01%. These results demonstrate that anatomically informed shape matching coupled with stress-based chordal calibration can reproduce tricuspid valve closure without explicit subject-specific chordal geometry. This framework provides a foundation for generating synthetic subvalvular anatomy for future imaging-derived, predictive tricuspid valve models.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Patient-specific Modeling of the Tricuspid Valve from 3D Transesophageal EchocardiographyarXiv · 2026
- Effect of Parametric Variation of Chordae Tendineae Structure on Simulated Atrioventricular Valve Closure.Annals of biomedical engineering · 2026
- Tricuspid Valve Chordae Tendineae: Where are They, How Many are There, and What are Their Properties?bioRxiv · 2026
- A Study on the Measurement of Calcification in Bicuspid Aortic ValvesCurrent Directions in Biomedical Engineering · 2026
- In silico modeling of transcatheter heart valve oversizing and ellipticity, Part I: Establishing credibility of an advanced modelComputer Methods and Programs in Biomedicine · 2026
- Shape-informed cardiac mechanics surrogates in data-scarce regimes via geometric encoding and generative augmentationnpj Digital Medicine · 2026