Joint Poisson Reconstruction for Prompt-Gamma-Enabled 68Ga/18F Dual-Isotope Quantitative PET Imaging
Yu Shi, Meng Niu, Sen Yang, Tengjiao Wang, Risheng Yang, Yanyun Liu, Wei Ding, Xiangyu Liu,
Key points
From the paper's conclusion- Conclusion: Joint estimation improved dual-isotope separation under the evaluated low-count conditions.
Abstract
Objective:To enable simultaneous quantitative 68Ga/18F PET imaging despite low prompt-gamma triple-coincidence counts and random-triple contamination. Methods: We developed an expectation-maximization reconstruction method (PNR-EM) that jointly estimates pure-emitter, non-pure-emitter, and random-triple components using a Poisson model of prompt double, prompt triple, and delayed triple measurements. A consistent-delay strategy estimates random triples while preserving true-pair temporal correlations. Prompt doubles additionally constrain the non-pure component, and total variation regularization suppresses reconstruction noise. The method was evaluated with quantitative and Derenzo phantoms, a nine-well separation phantom, and tumor-bearing mice. Results: Phantom quantitation showed strong linearity (r2>0.99) and a maximum relative deviation below 9.9% relative to single-isotope references. The separated images largely preserved rod resolvability relative to their corresponding single-isotope references. The best PSNR, SSIM, and RMSE were 33.72 dB, 0.975, and 0.0206 for 18F, and 34.86 dB, 0.955, and 0.0181 for 68Ga in the 9-well phantom. The 68Ga RMSE was 41.4% lower than that of the best image-domain separation baseline. Tumor-bearing mouse imaging demonstrated in vivo separation of 68Ga-DOTA-NOC and 18F-FDG distributions. Conclusion: Joint estimation improved dual-isotope separation under the evaluated low-count conditions. Significance: To our knowledge, this study provides the first experimental demonstration of simultaneous 68Ga/18F PET separation using prompt-gamma coincidences, supporting simultaneous imaging of complementary metabolic and receptor-targeted tracer distributions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Design and Performance Evaluation of a Quad-panel Dual-isotope PET Imaging SystemarXiv · 2026
- Regularization in multiplexed PET image reconstruction.Medical physics · 2026
- Benchmarking 18F and 68Ga Phantom Performance on a Digital Time-of-Flight PET/CT System: Reference Values for Spatial Resolution, Contrast Recovery, and Background Variability.Journal of nuclear medicine technology · 2026
- A Model-based Harmonization Strategy of Standard Uptake Values for Paired PET Studies.Phenomics (Cham, Switzerland) · 2026
- Count-aware diffusion with autoregressive inference for low-count PET reconstruction enhancement.Medical image analysis · 2026
- Joint a priori kinetic modeling with neural ODE for dual-tracer dynamic PET separation.Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society · 2026