A Model-based Harmonization Strategy of Standard Uptake Values for Paired PET Studies.
Tian Mou, Yuejie Lin, Fanghui Fan, Jian Huang, Taotao Sun, En-Tao Liu, Yi Gao
Guangdong Key Laboratory of Biomedical Measurements and Ultrasound Imaging, School of Biomedical Engineering, Shenzhen University, Shenzhen, 518060 Guangdong China. · Department of Food Science and Engineering, College of Chemistry and Environmental Engineering, Shenzhen University, Shenzhen, 518060 Guangdong China.
Key points
From the paper's conclusion- We collected paired imaging data from 37 patients, obtained using both PET/CT and PET/MR scanners.
Abstract
UNLABELLED: As both a diagnostic and quantitative monitoring tool, positron emission tomography (PET) imaging provides precise assessment for therapeutic efficacy in cancer management, neurological disorders, and cardiovascular diseases. In multicenter studies, the need for standardization of quantitative parameters of PET across systems is urgent. Systematic deviations from different scanners can compromise the consistency of imaging characteristics. The complex noise characteristics of clinical PET images, influenced by factors such as reconstruction protocols, scanner performance, and human factors, pose a challenge to the reliability of multicenter comparison studies. This study proposes a harmonization strategy aimed at improving the comparability of PET images from different sources. We present a model-based technique for normalizing PET images and assessing the measurement uncertainties in clinically relevant variables, specifically, SUV. Our approach successfully harmonizes SUV across different imaging modalities. We collected paired imaging data from 37 patients, obtained using both PET/CT and PET/MR scanners. The images show notable differences in statistical characteristics between scanners. The harmonization results show that the difference in SUV for phantom data decreased from the original value of 5.54± 5.43 to -0.06 ± 0.87, and the difference in SUV for patient data decreased from the original value of 3.95± 9.55 to -0.11± 1.10. Our method is able to improve the comparability of corresponding cases. It has demonstrated the efficiency of harmonization on paired PET images and suggests a potential application in multicenter PET studies. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at https://doi.org/10.1007/s43657-025-00289-8.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A harmonisation framework for multi-centre preclinical PET imaging across a national research infrastructure.Physics in medicine and biology · 2026
- Standardization and quality control in PET imaging: Advances, challenges, and clinical implications.Radiography (London, England : 1995) · 2026
- Impact of dose reduction and multi‐parametric harmonization on multi‐organ radiomics robustness in total‐body PET imaging: Methodological implications for quantitative theranosticsMedical Physics · 2026
- Preclinical PET and SPECT Imaging in Small Animals: Technologies, Challenges and Translational ImpactCells · 2025
- Test-Retest Repeatability of [18F]FDG Uptake by Solid Tumors on PET/MRI: A Prospective, Multicenter Study Using the QIBA Protocol.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2026
- Metabolic Tumor Volume Is More Accurate Than SUV Metrics in PSMA-PET/CT Analysis Across Different PET/CT Scanners.Clinical nuclear medicine · 2026