Regularization in multiplexed PET image reconstruction.
Jackson W Foster, Wen He, Garry Chinn, Craig S Levin
Department of Electrical Engineering, Stanford University, Stanford, California, USA. · Molecular Imaging Program, Department of Radiology, Stanford University, Stanford, California, USA.
Key points
From the paper's conclusion- We will demonstrate the use of regularization in simultaneously acquired multi‐tracer m PET data reconstruction.
Abstract
BACKGROUND: Multiplexed PET (mPET) using one tracer labeled with a positron plus prompt gamma ray emitter is limited by low sensitivity to triple-photon coincidences (two annihilation photons and one prompt gamma photon), leading to high noise in the reconstructed images. PURPOSE: The use of regularization has been previously shown to increase the image quality of single tracer PET images under low signal-to-noise ratio conditions. We will demonstrate the use of regularization in simultaneously acquired multi-tracer mPET data reconstruction. METHODS: First, we present how a maximum a posteriori expectation maximization solution can be obtained for simultaneously acquired multi-isotope PET data. Next, we use a Monte Carlo simulation of an image quality phantom mPET acquisition with a pure positron (18F) and a positron plus prompt gamma (44Sc) emitter to evaluate the performance of different regularization methods. RESULTS: For a baseline regularization method to simultaneously reconstruct both activity distributions, we show that a relative difference penalty (RDP) provides the best tradeoff of the penalty functions tested in image quality and quantitative accuracy for a simulated hot sphere phantom compared to quadratic and log-cosh penalty functions, with a contrast-to-noise ratio (CNR) in 18F/44Sc of over 60% higher on average for the RDP compared to the quadratic penalty in the largest spheres. However, this regularization approach has up to 2x worse reconstructed inter-tracer crosstalk ratio compared to unregularized reconstruction. Finally, we present a further optimization by alternating reconstruction of the two individual tracer images with regularization to achieve a CNR in the largest 18F/44Sc spheres with an up to 35% improvement on average over the simultaneous RDP-based regularization reconstruction results described above, while maintaining a 10%-20% lower inter-tracer crosstalk ratio over the unregularized reconstruction. CONCLUSIONS: For the selected radionuclides, simulated system and phantom, we demonstrate proof-of-principle that using regularization applied to an alternating update form of EM achieves significantly higher CNR in both tracers compared to unregularized alternating update OSEM and regularized simultaneous OSEM, with significantly lower crosstalk in the prompt gamma emitter reconstruction than the regularized simultaneous OSEM.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Joint Poisson Reconstruction for Prompt-Gamma-Enabled 68Ga/18F Dual-Isotope Quantitative PET ImagingarXiv · 2026
- Bayesian Image Reconstruction and Uncertainty Quantification for Three-Photon Positronium Ratio Imaging: Toward Radiotheranostic ApplicationsarXiv · 2026
- Sinogram-based regularization parameter learning for 2D penalized maximum-likelihood PET image reconstruction.Physics in medicine and biology · 2026
- Per-Bundle Statistical Limits and Learned-Prior Inversion in Multiplexed X-ray Imaging, with Application to Temporal CT.Physics in medicine and biology · 2026
- Roadmap: Image reconstruction in emission tomography for the era of fast Monte Carlo simulationarXiv · 2026
- PET/MR: history, current state, and technologyBritish Journal of Radiology · 2026