A wearable, stretchable radio-frequency coil for extremity imaging in low-field MRI systems
Jesús Conejero, Marina Fernández-García, José Borreguero, Teresa Guallart-Naval, Pablo García-Cristóbal, Lorena Vega-Cid, Eli G. Castañón, Rubén Bosch,
Key points
From the paper's conclusion- Purpose: To develop a wearable, stretchable radio-frequency (RF) coil that conforms to the extremities and improves the filling factor in low-field MRI.
Abstract
Purpose: To develop a wearable, stretchable radio-frequency (RF) coil that conforms to the extremities and improves the filling factor in low-field MRI. Methods: A stretchable solenoid RF coil was fabricated by stitching a sinusoidally arranged Litz-wire conductor onto an elastic textile. The coil was compared with four rigid coils, including two routinely used designs and two prototypes designed to isolate the effects of conductor material and stretchability. Performance was characterized through quality-factor, loading-factor, transmit-efficiency, and image-based signal-to-noise ratio (SNR) measurements. Phantom and in-vivo knee experiments for one volunteer were performed using two portable MRI systems operating at 3.53 and 3.04 MHz. Results: The electrical performance of the selected Litz wire decreased with increasing frequency, becoming a slight disadvantage at 3.53 MHz. Nevertheless, the stretchable coil provided the highest phantom SNR in both systems, exceeding that of the best-performing rigid coil by approximately 8 % at 3.53 MHz and 20 % at 3.04 MHz. In vivo, its global SNR was 5 % lower than that of the best rigid coil at 3.53 MHz and 19 % higher at 3.04 MHz. Compared with the larger rigid coil required when knee positioning is constrained, the corresponding SNR improvements were approximately 18 % and 80 %. Conclusion: Anatomical conformity can compensate for the frequency-dependent electrical limitations of Litz wire in stretchable low-field RF coils. The proposed design provided SNR comparable to or greater than the best rigid designs while facilitating coil placement in subjects for whom smaller rigid coils may be impractical.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Frequency Selective Surface (FSS) radiofrequency shield for low-field MRI.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2026
- Evaluation of a modular flexible coil for thoracic outlet syndrome MRI at 3 T.Magma (New York, N.Y.) · 2026
- Development of RF Probes and Preamplifiers for MRI at Low FieldsNMR in Biomedicine · 2026
- A Near‐Field Coupling Array Enables Parallel Imaging and SNR Gain in MRI (Adv. Sci. 37/2025)Advanced Science · 2025
- A High-Performance Conformal Metamaterial for 1.5 T Wrist Magnetic Resonance Imaging.ACS applied materials & interfaces · 2026
- Diagnostic Performance of a Metasurface Coil Compared With a Commercial 12-Channel Coil for Knee MRI at 1.5 T.Journal of magnetic resonance imaging : JMRI · 2026