Evaluation of a modular flexible coil for thoracic outlet syndrome MRI at 3 T.
Catherine Truong, Bouchra Assabah, Pedro Teixeira, Audrey Kirsch, Pierre-André Vuissoz, Romain Gillet, Elmar Laistler, Jacques Felblinger,
SIEMENS Healthcare SAS, Courbevoie, France. · IADI, Université de Lorraine, U1254 INSERM, 54000, Nancy, France.
Key points
From the paper's conclusion- Overall, modular flexible coils support faster, higher-quality dynamic TOS MRI protocols, potentially improving diagnostic reliability, and patient comfort.
Abstract
Thoracic outlet syndrome (TOS) results from compression of neurovascular structures. Dynamic MRI may enhance diagnostic accuracy; however, conventional rigid coils are suboptimal for imaging during functional maneuvers. This study compared a custom-built flexible modular coil (ModFlex) with a conventional torso coil, focusing on the interscalene (ISS) and costoclavicular spaces (CCS). Nine healthy volunteers participated in 3 T TOS MRI using both coils. The signal-to-noise ratio (SNR) was calculated in two regions of interest (ISS and CCS). Additionally, g-factors were evaluated for simulated GRAPPA parallel imaging factors from 3 to 6. Two clinicians visually rated T1-weighted sagittal images to assess ModFlex coil performance. Quantitative data were compared using the Wilcoxon signed-rank and the ranks with the sign test. The ModFlex demonstrated a significantly higher SNR in the CCS (+ 39%, p = 0.004), a trend toward higher SNR in the ISS (+ 17%, p = 0.098), and significantly lower g-factors (i.e., higher parallel imaging performance) across all acceleration levels (p < 0.008). The clinicians' evaluation was generally consistent with quantitative findings, although not conclusive. GRAPPA acceleration provided better image quality than SMS (p = 0.008). Overall, modular flexible coils support faster, higher-quality dynamic TOS MRI protocols, potentially improving diagnostic reliability, and patient comfort.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Highly Superficial Flexible Coil Array for 1.5T MRI: Diagnostic Quality Evaluation Compared to Conventional Technology.IEEE transactions on bio-medical engineering · 2026
- A wearable, stretchable radio-frequency coil for extremity imaging in low-field MRI systemsarXiv · 2026
- Augmented 3T imaging performance of the Temporomandibular joint using wireless resonators.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2026
- Diagnostic Performance of a Metasurface Coil Compared With a Commercial 12-Channel Coil for Knee MRI at 1.5 T.Journal of magnetic resonance imaging : JMRI · 2026
- Evaluation of a novel flexible, lightweight blanket-like torso coil in pediatric MRI at 1.5-T - initial experience.Pediatric radiology · 2026
- Phantom imaging performance and initial in vivo feasibility of an anatomy-conforming dentomaxillofacial prototype coil for dental MRIBMC Medical Imaging · 2026