Journal of the American Academy of Orthopaedic Surgeons. Global research & reviews

Methods for Biomechanical Testing of Fifth Metatarsal Fracture Fixation: A Scoping Review.

Phillip Schmitt, Carrie Hinchman, Brad Blankenhorn, Raymond Hsu

From the Department of Orthopaedic Surgery, The Warren Alpert Medical School of Brown University, Providence, RI.

Review

Key points

From the paper's conclusion
  • Biomechanical studies of fifth MT fracture fixation demonstrated considerable methodological heterogeneity, limiting cross-study comparison and clinical translation. Future studies should standardize methodology, isolate individual implant variables, and employ physiologically relevant cyclic loading models to improve reproducibility and clinical relevance.

Abstract

BACKGROUND: Zone 2 and proximal zone 3 fractures of the fifth metatarsal (MT) are frequently managed with surgical fixation, particularly in young, active patients. Although numerous biomechanical studies have evaluated fixation strategies, heterogeneity in experimental design limits meaningful comparison and consensus regarding optimal fixation parameters. HYPOTHESIS/PURPOSE: The purpose of this study was to systematically characterize the methodologies used in biomechanical cadaveric studies of zone 2 and proximal zone 3 fifth MT fracture fixation and to identify sources of variability that limit cross-study comparison and clinical translation. METHODS: A scoping review of publications before July 2025 was done. PubMed/Medline and Embase Ovid databases were searched for cadaveric biomechanical studies evaluating fixation constructs for fifth MT fractures. Data were extracted on study design, bone density assessment, construct preparation, implant selection, load testing methods, outcome measures, and study conclusions. RESULTS: Thirteen biomechanical studies published between 1999 and 2023 were included. Most studies evaluated variations of intramedullary screw fixation. Substantial variability was observed in selection of screw dimensions, specimen handling, and bone density assessment. Load testing protocols varied widely with respect to loading mode, load magnitude, cycle count, and use of cyclic versus load-to-failure testing. Study outcomes were inconsistent, with no clear superiority demonstrated among fixation constructs or implant design variables. CONCLUSION: Biomechanical studies of fifth MT fracture fixation demonstrated considerable methodological heterogeneity, limiting cross-study comparison and clinical translation. Future studies should standardize methodology, isolate individual implant variables, and employ physiologically relevant cyclic loading models to improve reproducibility and clinical relevance. STUDY DESIGN: Scoping review.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers