Methods for Biomechanical Testing of Fifth Metatarsal Fracture Fixation: A Scoping Review.
Phillip Schmitt, Carrie Hinchman, Brad Blankenhorn, Raymond Hsu
From the Department of Orthopaedic Surgery, The Warren Alpert Medical School of Brown University, Providence, RI.
Key points
From the paper's conclusion- Biomechanical studies of fifth MT fracture fixation demonstrated considerable methodological heterogeneity, limiting cross-study comparison and clinical translation. Future studies should standardize methodology, isolate individual implant variables, and employ physiologically relevant cyclic loading models to improve reproducibility and clinical relevance.
Abstract
BACKGROUND: Zone 2 and proximal zone 3 fractures of the fifth metatarsal (MT) are frequently managed with surgical fixation, particularly in young, active patients. Although numerous biomechanical studies have evaluated fixation strategies, heterogeneity in experimental design limits meaningful comparison and consensus regarding optimal fixation parameters. HYPOTHESIS/PURPOSE: The purpose of this study was to systematically characterize the methodologies used in biomechanical cadaveric studies of zone 2 and proximal zone 3 fifth MT fracture fixation and to identify sources of variability that limit cross-study comparison and clinical translation. METHODS: A scoping review of publications before July 2025 was done. PubMed/Medline and Embase Ovid databases were searched for cadaveric biomechanical studies evaluating fixation constructs for fifth MT fractures. Data were extracted on study design, bone density assessment, construct preparation, implant selection, load testing methods, outcome measures, and study conclusions. RESULTS: Thirteen biomechanical studies published between 1999 and 2023 were included. Most studies evaluated variations of intramedullary screw fixation. Substantial variability was observed in selection of screw dimensions, specimen handling, and bone density assessment. Load testing protocols varied widely with respect to loading mode, load magnitude, cycle count, and use of cyclic versus load-to-failure testing. Study outcomes were inconsistent, with no clear superiority demonstrated among fixation constructs or implant design variables. CONCLUSION: Biomechanical studies of fifth MT fracture fixation demonstrated considerable methodological heterogeneity, limiting cross-study comparison and clinical translation. Future studies should standardize methodology, isolate individual implant variables, and employ physiologically relevant cyclic loading models to improve reproducibility and clinical relevance. STUDY DESIGN: Scoping review.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biomechanical Evaluation of Crossed Screw Fixations With Different Head Designs for First Tarsometatarsal Joint Arthrodesis.Foot & ankle specialist · 2026
- Intraarticular calcaneal fractures: biomechanical analysis of two fixation constructs.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2026
- Internal Fixation Bone Mass Index (IFBM) and Biomechanical Performance of Different Fixation Methods for Herscovici Type B and Type C Medial Malleolar Fractures.The Journal of foot and ankle surgery : official publication of the American College of Foot and Ankle Surgeons · 2026
- Biomechanical comparison of mini-plate and screw fixation in minimally invasive distal metatarsal osteotomy for hallux valgus : a finite element and cadaveric study.Bone & joint research · 2026
- Development and biomechanical study of a novel tibial external fixation device in synthetic tibial fracture models.Clinical biomechanics (Bristol, Avon) · 2026
- Fixation of Zone 2 Sacral Fractures Utilizing a Novel Compressive Bolt - A Biomechanical Comparison.Journal of orthopaedic trauma · 2026