Effect of leaded gloves on patient and surgeon radiation exposure in percutaneous nephrolithotomy: A prospective pilot study.
Luke A Brawer, Johnny Wang, Matthew Skalak, Joel Vetter, Ethan Vargo
Washington University in St. Louis School of Medicine, St. Louis, Missouri, United States of America.
Key points
From the paper's conclusion- In this pilot study, leaded glove use was associated with a significant and consistent increase in patient collar radiation across all measurement depths. The non-significant reduction in surgeon hand exposure should be interpreted cautiously given limited statistical power. These findings do not support routine leaded glove use during PCNL, and adequately powered studies are needed to confirm these findings and identify optimal radiation protection strategies.
Abstract
INTRODUCTION: Ionizing radiation exposure is a significant occupational hazard for urologists performing percutaneous nephrolithotomy (PCNL). Surgeon hands are particularly vulnerable during fluoroscopic access. Leaded gloves are a proposed mitigation strategy. This prospective pilot study evaluated surgeon hand and patient collar radiation exposure during PCNL with standard vs leaded gloves. MATERIAL AND METHODS: Twenty patients were prospectively allocated to standard or leaded glove groups in sequential fashion. All cases were performed by a single high-volume endourologist with patients in the prone position. Clinical variables including BMI, operative time, stone size, and fluoroscopy dose were recorded. Surgeon hand exposure was measured using ring dosimeters. Patient exposure was measured with clip-on dosimeters at the collar, reported as deep dose equivalent (DDE), lens dose equivalent (LDE), and shallow dose equivalent (SDE). RESULTS: At baseline, patient BMI (p = 0.005) and fluoroscopy radiation dose (p <0.001) were greater in the standard glove group. There was no significant difference in surgeon hand exposure at the right (p = 0.143) or left hand (p = 0.608). Leaded gloves were associated with a significant increase in patient collar radiation at DDE (p = 0.002), LDE (p = 0.009), and SDE (p = 0.009). CONCLUSIONS: In this pilot study, leaded glove use was associated with a significant and consistent increase in patient collar radiation across all measurement depths. The non-significant reduction in surgeon hand exposure should be interpreted cautiously given limited statistical power. These findings do not support routine leaded glove use during PCNL, and adequately powered studies are needed to confirm these findings and identify optimal radiation protection strategies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation of occupational radiation exposure and safety practices among orthopedic surgeons using C-arm fluoroscopy: a preliminary study at a hospital in Palestine.Radiation protection dosimetry · 2026
- Assessment of Anesthesia Providers' Radiation Safety Practices Using Operating Room Black Box Data.Workplace health & safety · 2026
- Clinical evaluation of radiation-shielding effects of a head-and-neck X-ray protective device during cardiovascular interventional procedures.Radiological physics and technology · 2026
- Basal cell carcinoma and squamous cell carcinoma of the hands in an orthopedic surgeon with occupational radiation exposure from C-arm fluoroscopy in Korea: a case report.Annals of occupational and environmental medicine · 2026
- Spatial distribution of X-ray attenuation in a full-face shield: a multipoint in vivo study in interventional cardiology.Radiation protection dosimetry · 2026
- Evaluating Standard Shielding Versus Novel Enhanced Radiation Protection Devices in the Cardiac Catheterization Laboratory.Journal of the American Heart Association · 2026