Journal of clinical and experimental dentistry

Does manufacturing specialization matter? Transfer accuracy of static surgical guides produced by general-purpose and dental-specific additive workflows: A paired in vitro study.

Mario Guerrero-Torres, Andrés Portilla-Suárez, César Augusto Ortiz-Prada, Boris Damian Jaimes-Parra, Néstor Ríos-Osorio

Facultad de Odontología, Universidad Santo Tomás, Bucaramanga, Colombia. · School of Medicine, Universidad Autónoma de Bucaramanga, Bucaramanga, Colombia.

Preclinical

Key points

From the paper's conclusion
  • Under the controlled conditions of this paired in vitro study, static guided placement reduced transfer deviation compared with freehand placement. No statistically significant difference was detected between the two guided workflows; however, the study was not designed to establish equivalence or non-inferiority.

Abstract

BACKGROUND: Transfer accuracy in static computer-assisted implant surgery reflects errors accumulated during imaging, planning, guide design, manufacturing, seating, and execution. This paired in vitro study compared freehand placement with static guidance produced by two additive-manufacturing workflows: A general-purpose workflow using equipment, software, and resin not indicated for dental surgical guides and a dental-specific workflow using dedicated components and surgical-guide resin. MATERIALS AND METHODS: Twenty-four independent physical models were arranged in eight anatomical blocks, with one geometry-equivalent model assigned to each condition within every block: Freehand placement (FH), guided placement using a general-purpose workflow (GP), and guided placement using a dental-specific workflow (DS). Planned and achieved positions were registered three-dimensionally, and coronal, apical, and angular deviations were calculated. Friedman tests were followed by three two-sided Wilcoxon signed-rank comparisons with Holm adjustment. RESULTS: Mean coronal deviations were 1.74 ± 0.34 mm for FH, 0.38 ± 0.23 mm for GP, and 0.40 ± 0.19 mm for DS. Corresponding apical deviations were 1.81 ± 0.34, 0.58 ± 0.25, and 0.54 ± 0.22 mm, and angular deviations were 8.69 ± 1.52°, 3.04 ± 0.50°, and 3.10 ± 0.44°, respectively. Both guided conditions produced lower deviations than FH for all three outcomes (all Holm-adjusted p=0.0234). No statistically significant differences were detected between GP and DS for coronal, apical, or angular deviation. CONCLUSIONS: Under the controlled conditions of this paired in vitro study, static guided placement reduced transfer deviation compared with freehand placement. No statistically significant difference was detected between the two guided workflows; however, the study was not designed to establish equivalence or non-inferiority.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Does manufacturing specialization matter? Transfer accuracy of static surgical guides produced by general-purpose and dental-specific additive workflows: A paired in vitro study — Science Skim