Beyond Gamma Analysis: An Accessibility-oriented Framework for Comparative Evaluation of Patient-specific Radiotherapy Quality Assurance.
Vikram, Raj Pal Singh, Manindra Bhushan
Department of Physics, GLA University, Mathura, Uttar Pradesh, India. · Department of Radiation Oncology, Division of Medical Physics, Rajiv Gandhi Cancer Institute and Research Center, New Delhi, India.
Key points
From the paper's conclusion- Software-based QA approaches significantly improved operational efficiency and accessibility while maintaining clinically acceptable dosimetric agreement. However, further prospective, multi-institutional validation of the proposed accessibility framework is warranted.
Abstract
BACKGROUND: Patient-specific quality assurance (QA) in radiotherapy is traditionally performed using measurement-based systems that require dedicated hardware, machine time, and manpower. Although software-based QA approaches have emerged as efficient alternatives, their comparative accessibility and operational performance remain insufficiently investigated. This study evaluated conventional and software-based QA methodologies using integrated dosimetric, temporal, and economic metrics. MATERIALS AND METHODS: A total of 90 clinically approved treatment plans, including head-and-neck, pelvis, and lung volumetric modulated arc therapy/stereotactic body radiotherapy cases, were retrospectively analysed. All plans were generated in Eclipse TPS v15.6 and evaluated using ArcCHECK phantom-based QA, electronic portal imaging device (EPID)-based QA, and log file-based QA. Gamma analysis was performed using 3%/2 mm criteria with a 10% dose threshold. Workflow time and relative cost burden were recorded for each method. Three composite indices were defined: QA Cost Efficiency Index (QCEI), QA Efficiency Index (QEI), and QA Accessibility Index (QAI). Statistical comparisons were performed using paired analysis with Bonferroni correction. RESULTS: All QA methods achieved clinically acceptable gamma passing rates. Log file-based QA demonstrated the highest median gamma passing rate; however, the absolute differences between methodologies were small, and all approaches exceeded the predefined clinical acceptance criterion (≥95%). ArcCHECK showed the greatest workflow time and cost burden, whereas log file-based QA demonstrated the highest QCEI, QEI, and QAI values. EPID-based QA showed intermediate performance. All pairwise differences in accessibility metrics were statistically significant (P < 0.05). CONCLUSION: Software-based QA approaches significantly improved operational efficiency and accessibility while maintaining clinically acceptable dosimetric agreement. However, further prospective, multi-institutional validation of the proposed accessibility framework is warranted.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Independent Three-dimensional Dose Calculation from Log Files for Breast VMAT: A Measurement-free Quality Assurance Approach.Journal of medical physics · 2026
- Evidence-based design of a patient-specific quality assurance program through retrospective analysis of pretreatment and in vivo results.Physics and imaging in radiation oncology · 2026
- Assessment of Clinical Quality Metrics for IROC Houston SRS Phantom Performance EvaluationDigital Commons-TMC (Texas Medical Center) · 2026
- It’s not your device, it’s how you use it – Sensitivity and specificity of PSQA devices in the SEAFARER head and neck studyRadiotherapy and Oncology · 2026
- API-enabled integration of Pylinac with QATrack+ for automated EPID-based QA on Elekta linear accelerators: a technical note.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2026
- ESTRO-EPTN guidelines for independent dose calculation and log file-based patient-specific quality assurance in scanned particle therapy.Physics and imaging in radiation oncology · 2026