Evidence-based design of a patient-specific quality assurance program through retrospective analysis of pretreatment and in vivo results.
Esther Decabooter, Sebastiaan M J J G Nijsten
Maastro, Maastricht Radiation Oncology Institute, Maastricht, The Netherlands.
Key points
From the paper's conclusion- This retrospective analysis demonstrated that a comprehensive framework incorporating independent, purpose-specific PSQA methods is essential to detect a wide range of treatment deviations. Combining complementary methods improves the reliability and interpretability of results. The clinical impact of a PSQA program can be further enhanced by adopting more clinically meaningful evaluation metrics and using the results to guide the optimization of new treatment strategies.
Abstract
BACKGROUND AND PURPOSE: As radiotherapy techniques become increasingly complex, patient-specific quality assurance (PSQA) must evolve to detect a broad spectrum of potential failure modes across the treatment chain. This study presents a extensive evaluation of a multi-modal PSQA program by assessing its ability to detect clinically relevant failure modes and quantifying its efficacy. MATERIALS AND METHODS: A five-year retrospective analysis was conducted of an integrated PSQA program implemented at Maastro, combining secondary dose calculations, log-file based verification, and Electronic Portal Dosimetry (EPD) in both pretreatment and in vivo workflows. The efficacy of individual QA methods and the overall program was quantified using positive predictive values (PPVs). PSQA outcomes were linked to potential improvements in treatment planning strategies and delivery techniques. RESULTS: A total of 18,558 treatment plans were analyzed in the pretreatment workflow and 1817 treatment plans in the in vivo workflow. Nearly all high-priority failure modes could be detected except machine output miscalibration. Combining PSQA methods substantially improved PPVs across failure categories. The in vivo workflow flagged the most failure modes and additionally gives insight into possible improvements in planning strategies or treatment techniques. CONCLUSIONS: This retrospective analysis demonstrated that a comprehensive framework incorporating independent, purpose-specific PSQA methods is essential to detect a wide range of treatment deviations. Combining complementary methods improves the reliability and interpretability of results. The clinical impact of a PSQA program can be further enhanced by adopting more clinically meaningful evaluation metrics and using the results to guide the optimization of new treatment strategies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- It’s not your device, it’s how you use it – Sensitivity and specificity of PSQA devices in the SEAFARER head and neck studyRadiotherapy and Oncology · 2026
- Beyond Gamma Analysis: An Accessibility-oriented Framework for Comparative Evaluation of Patient-specific Radiotherapy Quality Assurance.Journal of medical physics · 2026
- Independent Three-dimensional Dose Calculation from Log Files for Breast VMAT: A Measurement-free Quality Assurance Approach.Journal of medical physics · 2026
- Five years of clinical application of independent Monte Carlo-based patient-specific quality assurance at Maastro Proton Therapy Center.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026
- ESTRO-EPTN guidelines for independent dose calculation and log file-based patient-specific quality assurance in scanned particle therapy.Physics and imaging in radiation oncology · 2026
- A pathway away from measurement‐based patient‐specific QA: A review of contemporary quality assurance for external‐beam radiotherapy sub‐systemsJournal of Applied Clinical Medical Physics · 2025