Influencing Factors of Positional Stability of Implantable Collamer Lenses in Terms of Rotation, Decentration, and Tilt in Patients With Myopia.
Liyin Wang, Yuhao Ye, Fang Liu, LingLing Niu, Wanru Shi, Peijun Yao, Xiaoying Wang, Xingtao Zhou,
Shanghai Institute of Infectious Disease and Biosecurity, Fudan University, Shanghai, China. · Department of Ophthalmology and Vision Science, Eye and ENT Hospital, Fudan University, Shanghai, China.
Key points
From the paper's conclusion- ICL positional stability was within an acceptable range. ICL fixation angle and the structures of the iris and ciliary body influenced the rotation, decentration, and tilt of the ICL. Abnormal vault values were also correlated with ICL rotation and tilt.
Abstract
PURPOSE: To quantitatively assess the positional stability, including rotation, decentration, and tilt, of Implantable Collamer Lenses (ICLs) and analyze the influencing ocular parameters. METHODS: Ninety-two eyes were enrolled in this prospective study. Preoperative ocular parameters were measured and the ICL positional stability was evaluated, including rotation, decentration, and tilt during a 6-month follow-up using the OPD-Scan III (Nidek) and Casia2 (Tomey). Correlations between ocular parameters, vault, and ICL positional stability were explored. RESULTS: The mean ICL vault, rotation, decentration, and tilt at 6 months postoperatively were 633.28 ± 211.96 µm, 4.37 ± 3.04°, 0.31 ± 0.16 mm, and 2.67 ± 0.89°, respectively. For rotation, ICL fixation angle (β = 0.894, P = .01) and ciliary sulcus angle (β = 0.043, P = .033) were significant. For decentration, axial length (β = 0.023, P = .027), sulcus-to-sulcus distance (β = -0.109, P = .004), and iris concavity (β = 0.481, P < .001) were independent factors. For tilt, univariate linear regression analyses indicated significant correlations with iris-to-ciliary process distance (β = 0.001, P = .002). RCS analysis revealed a non-linear relationship between vault and ICL rotation and tilt: rotation was greater at vaults <400 and >800 µm, whereas tilt was greater at vaults <400 µm. Low vault (<400 µm) was also a correlated factor for ICL tilt. CONCLUSIONS: ICL positional stability was within an acceptable range. ICL fixation angle and the structures of the iris and ciliary body influenced the rotation, decentration, and tilt of the ICL. Abnormal vault values were also correlated with ICL rotation and tilt.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biometric and ICL-related risk factors associated with suboptimal vault with implantable collamer lenses.Frontiers in medicine · 2026
- Rotational Stability and Vault Outcomes of the EVO ICL Using Oblique Implanting Orientation Compared to Horizontal/Vertical Implanting OrientationJournal of Refractive Surgery · 2026
- Risk Factors Associated With ICL Decentration After ICL Surgery.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Characteristics of the Haptic Position and Its Impact on Vault After Horizontal or Vertical ICL Implantation.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Research on a New Model for Predicting Vault After Implantable Collamer Lens (ICL) Based on Structural Parameters of the Posterior Chamber.Journal of ophthalmology · 2026
- Rotational stability and visual outcomes of toric implantable collamer lenses in eyes with horizontal and non-horizontal implanting orientation: an observational study.International ophthalmology · 2026