Risk Factors Associated With ICL Decentration After ICL Surgery.
Junfeng Li, Yichen Xiao, Rui Xiong, Chang Liu, Ziyi Guo, Zhuotong Wu, Xingtao Zhou, Shengtao Liu
Department of Ophthalmology, Eye and Ear, Nose, and Throat Hospital of Fudan University, Xuhui District, Shanghai, China. · The Affiliated Eye Hospital, Jiangxi Medical College, Nanchang University, Jiangxi Eye Hospital, Jiangxi Institute of Ophthalmology and Visual Science, Nanchang, China.
Key points
From the paper's conclusion- ICL decentration after surgery is generally small but varies between individuals; angle alpha is the main predictor of decentration, and preoperative measurement of angles alpha and kappa helps identify patients at higher risk.
Abstract
PURPOSE: To evaluate the magnitude and direction of Implantable Collamer Lens (ICL V4c; STAAR Surgical) decentration at 1 month after implantation and to identify associated preoperative biometric factors. METHODS: This prospective observational study included 52 patients (104 eyes) receiving ICL V4c implantation. Preoperative measurements included corneal curvature, anterior chamber depth, white-to-white distance, axial length, and angle alpha and angle kappa. One month postoperatively, total, horizontal, and vertical decentrations of the ICL center relative to the visual axis were measured using the OPD-Scan III (Nidek). Generalized estimating equations (GEEs) were used to analyze relationships between decentration and biometric variables while accounting for inter-eye correlation. RESULTS: The mean total decentration was 0.43 ± 0.19 mm and was predominantly temporal; mean horizontal and vertical decentrations were -0.24 ± 0.32 and 0.05 ± 0.24 mm, respectively. GEE analysis showed that the magnitude of angle alpha was significantly correlated with total decentration (coefficient = 0.669, β = 0.422; adjusted R2 = 0.159; P < .001), that horizontal decentration was related to the horizontal components of angles alpha and kappa (adjusted R2 = 0.415), and that vertical decentration was related to the vertical component of angle kappa (adjusted R2 = 0.075). Eyes with angle alpha greater than 0.50 mm exhibited greater decentration. CONCLUSIONS: ICL decentration after surgery is generally small but varies between individuals; angle alpha is the main predictor of decentration, and preoperative measurement of angles alpha and kappa helps identify patients at higher risk.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Influencing Factors of Positional Stability of Implantable Collamer Lenses in Terms of Rotation, Decentration, and Tilt in Patients With Myopia.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Assessment of Chord Mu and Chord Alpha in Relation to Post-ICL Implantation Visual Quality.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Investigation of ciliary body inner diameter in Chinese myopic adults using ArcScan Insight® 100.Frontiers in medicine · 2026
- Effect of implantable collamer lens on biometric measurements and intraocular lens power calculation formulas.Acta ophthalmologica · 2026
- Biometric and ICL-related risk factors associated with suboptimal vault with implantable collamer lenses.Frontiers in medicine · 2026
- Long-term Efficacy and Safety of the Implantable Collamer Lens in Eyes With an Anterior Chamber Depth of 2.6 to 2.8 mm.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026