International ophthalmology

Rotational stability and visual outcomes of toric implantable collamer lenses in eyes with horizontal and non-horizontal implanting orientation: an observational study.

Xiaoe Fan, Teruko Fukuyama, Lingling Niu, Xiaohong Zheng, Zhe Zhang, Jing Zhao, Xingtao Zhou

Department of Ophthalmology, Jincheng People's Hospital, Jincheng, 048026, Shanxi, China. fanxiaoe926@163.com. · Department of Ophthalmology, Eye & ENT Hospital, Fudan University, 83 Fenyang Road, Shanghai, 200031, China.

Observational · n=77

Key points

From the paper's conclusion
  • Non-horizontal EVO-TICL implantation yields rotational stability, safety and efficacy comparable to horizontal placement over 3 months, with small mean rotations and tight refractive predictability. These findings support non-horizontal orientation as a viable alternative when anatomy or vault optimization warrants it.

Abstract

PURPOSE: To evaluate the short-term rotational stability and visual outcomes of the toric intraocular collamer lens (TICL) with horizontal and non-horizontal implantation orientation based on the Callisto eye system. METHODS: This observational study analyzed 77 eyes from 51 patients with horizontal (n = 41) and non-horizontal (n = 36) TICL implantation. Examinations were performed preoperatively and at 1 week, 1 month, and 3 months. Outcomes included uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest refraction, and TICL axis position; rotational stability was quantified from dilated slit-lamp photographs. The primary endpoint was mean absolute rotation at 3 months. RESULTS: At 3 months, absolute rotation was 3.71 ± 2.72° (horizontal) and 3.15 ± 2.85° (non-horizontal), with no between-group difference (P = 0.385). Rotation ≤ 5° occurred in 73.17% (horizontal) and 88.89% (non-horizontal); ≤ 10° in 100% and 97.22%, respectively. Visual outcomes were excellent and comparable: at 3 months, UDVA 20/20 or better in 100% of eyes in both groups; efficacy index 1.19 ± 0.21 (horizontal) vs 1.17 ± 0.15 (non-horizontal); safety index 1.25 ± 0.21 vs 1.22 ± 0.19. Achieved refraction closely matched target (attempted-vs-achieved slope y = 1.02x + 0.01). Residual cylinder at 3 months was -0.42 ± 0.28 dioptres (D) (horizontal; within ±0.50 D in 87.8%, within ±1.00 D in 97.56%) and -0.33 ± 0.32 D (non-horizontal; within ±0.50 D in 94.44%, within ±1.00 D in 100%); difference non-significant (P = 0.156). CONCLUSION: Non-horizontal EVO-TICL implantation yields rotational stability, safety and efficacy comparable to horizontal placement over 3 months, with small mean rotations and tight refractive predictability. These findings support non-horizontal orientation as a viable alternative when anatomy or vault optimization warrants it.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Rotational stability and visual outcomes of toric implantable collamer lenses in eyes with horizontal and non-horizontal implanting orientation: an observational study — Science Skim