Characteristics of the Haptic Position and Its Impact on Vault After Horizontal or Vertical ICL Implantation.
Chiwen Cheng, Yichen Xiao, Ruoyan Wei, Rui Xiong, Lanhui Yu, Xiaoying Wang, Xingtao Zhou, Shengtao Liu
The Affiliated Eye Hospital, Jiangxi Medical College, Nanchang University. · Eye and ENT Hospital, Fudan University, Shanghai, China.
Key points
From the paper's conclusion- No statistically significant differences in haptic distribution patterns were observed between the horizontal and vertical implantation groups, whereas haptic position demonstrated significant correlations with central vault.
Abstract
PURPOSE: To evaluate the haptic positioning and its impact on postoperative vault after horizontal versus vertical Implantable Collamer Lens (ICL) implantation. METHODS: Eighty eyes (80 patients) undergoing ICL V4c (STAAR Surgical) implantation were stratified into horizontal (n = 40) and vertical (n = 40) groups. Ultrasound biomicroscopy measured ciliary sulcus-to-sulcus, crystalline lens to ciliary sulcus-to-sulcus, central vault (C-Vault), peripheral vault, and categorized haptic positions relative to ciliary anatomy (supratemporal, inferotemporal, supranasal, inferonasal). Statistical analyses compared intergroup differences and associations between parameters. RESULTS: Haptic distribution in the horizontal group varied by quadrant: 42.6% of haptics were in the ciliary sulcus (vs 40.8% vertical, P = .601), 29.4% of haptics were under the ciliary process (vs 23.7% vertical, P = .797), 21.8% of haptics were on the anterior angle of the ciliary process (vs 24.9% vertical, P = .302), and 6.1% of haptics were inserted into the ciliary process (vs 10.6% vertical, P = .023). The final tip of the ICL haptic negatively correlated with C-Vault in the horizontal (P = .009) and vertical (P = .049) groups, but showed no significant correlation with peripheral vault. CONCLUSIONS: No statistically significant differences in haptic distribution patterns were observed between the horizontal and vertical implantation groups, whereas haptic position demonstrated significant correlations with central vault.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Influencing Factors of Positional Stability of Implantable Collamer Lenses in Terms of Rotation, Decentration, and Tilt in Patients With Myopia.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Rotational Stability and Vault Outcomes of the EVO ICL Using Oblique Implanting Orientation Compared to Horizontal/Vertical Implanting OrientationJournal of Refractive Surgery · 2026
- Biometric and ICL-related risk factors associated with suboptimal vault with implantable collamer lenses.Frontiers in medicine · 2026
- Research on a New Model for Predicting Vault After Implantable Collamer Lens (ICL) Based on Structural Parameters of the Posterior Chamber.Journal of ophthalmology · 2026
- Different vault outcomes following implantable collamer lens implantation in eyes with ciliary body cysts: a case report.BMC ophthalmology · 2026
- Risk Factors Associated With ICL Decentration After ICL Surgery.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026