Zhuotong Wu, Ziyi Guo, Zhongjun Tang, Linda Zheng, Xingtao Zhou, Shengtao Liu
Neither preoperative chord mu nor chord alpha significantly affects higher order aberrations after ICL implantation, suggesting that the procedure has a relatively high tolerance regarding chord mu and chord alpha selection.
PURPOSE: To evaluate the clinical influence patterns of pre-operative chord mu and chord alpha on optical quality after Implantable Collamer Lens (ICL) (Visian; STAAR Surgical) implantation, thereby providing evidence-based guidance for surgical planning.
METHODS: This study included 92 patients (181 eyes) who underwent ICL implantation. The OPD-Scan III system (Nidek) was employed for the preoperative assessment of both chord mu and chord alpha. Changes in higher order aberrations were analyzed 3 months postoperatively. Postoperative optical aberration patterns were assessed for their dependence on preoperative chord mu and chord alpha measurements.
RESULTS: The mean value of chord mu was 0.25 ± 0.13 mm, and the median chord alpha was 0.22 mm (interquartile range: 0.19 mm). Chord mu exhibited a relatively dispersed distribution, whereas chord alpha was primarily distributed along the horizontal axis. Notably, 1/chord alpha exhibited a significant linear positive correlation with axial length (R2 = 0.1739, P < .001), reflecting the non-linear decay of chord alpha with axial elongation. The relationship was characterized by a generalized estimating equation using Gamma distribution and inverse link function. At 3 months postoperatively, analysis revealed statistically significant elevation in vertical coma and oblique trefoil (P < .05), whereas other optical parameters including total higher order aberrations, primary coma, trefoil, spherical aberration, and horizontal coma remained stable (P > .05). Correlation analysis revealed no significant association between changes in higher order aberrations and preoperative chord mu or chord alpha (P > .05).
CONCLUSIONS: Neither preoperative chord mu nor chord alpha significantly affects higher order aberrations after ICL implantation, suggesting that the procedure has a relatively high tolerance regarding chord mu and chord alpha selection.