Performance of the First Spiral Refractive Intraocular Lens for Continuous Full Range of Vision
Claudette Abela‐Formanek, Michael Amon, Gerd U. Auffarth, Başak Bostancı Ceran, Francesco Carones, Dean Corbett, Tiago B. Ferreira, Sanjay Mantry,
Medical University of Vienna · Sigmund Freud Privatuniversität Wien
Key points
From the paper's conclusion- To evaluate visual performance of a novel full range of vision spiral intraocular lens (IOL) designed with artificial intelligence using preclinical and clinical metrics.
Abstract
PURPOSE: To evaluate visual performance of a novel full range of vision spiral intraocular lens (IOL) designed with artificial intelligence using preclinical and clinical metrics. METHODS: Preclinical visual performance was assessed in healthy individuals using a pseudophakic vision simulation device, comparing monocular corrected distance visual acuity, contrast sensitivity, defocus curve, halo/glare size, and subjective preference between the spiral RayOne Galaxy IOL and diffractive RayOne Trifocal IOL (Rayner). Additionally, postoperative clinical outcomes were subsequently analyzed from 10 sites following bilateral RayOne Galaxy IOL implantation. At 3 months postoperatively, key endpoints included subjective refraction, monocular and binocular uncorrected and corrected distance visual acuity at multiple distances, defocus curves, and patient-reported dysphotopsia. RESULTS: Preclinical evaluation demonstrated comparable range of focus between the Galaxy and diffractive Trifocal IOLs. However, the Galaxy IOL exhibited significantly less halo/glare, with nearly all participants preferring it across all distances. In the clinical study, mean monocular corrected distance visual acuities were -0.03 ± 0.08 logarithm of the minimum angle of resolution (logMAR) for distance, 0.05 ± 0.11 logMAR for intermediate, and 0.08 ± 0.14 logMAR for near, with further improvement observed binocularly. Monocular/binocular defocus curves demonstrated a smooth plateau with binocular defocus maintaining visual acuity of 20/32 (0.2 logMAR) or better from +1.00 to -2.80 diopters (35 cm). Halo and glare symptoms were generally minor (> 95% of patients), with no severe cases. CONCLUSIONS: The Galaxy IOL provides excellent monocular and binocular visual acuity across all tested distances, with a smooth and continuous defocus curve ensuring full-range vision. Preclinical testing demonstrated significantly fewer photic phenomena than the tested diffractive trifocal IOL, whereas clinical investigations found no indications of bothersome side effects, together demonstrating high visual comfort.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical outcomes of a new presbyopia-correcting intraocular lens with spiral optic.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2026
- Quantitative framework for synthesising defocus-curve evidence in simultaneous-vision intraocular lenses.The British journal of ophthalmology · 2026
- Visual Performance of a Novel Intraocular Lens With Higher-Order Aspheric Design Optimized for Intermediate Vision.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Visual Performance and Patient-Reported Visual Function with Multifocal, Monofocal, and Enhanced Monofocal Intraocular Lenses.Journal of clinical medicine · 2026
- Ringless Premium Intraocular Lenses - a Narrative Review of Technological Advances.Maedica · 2026
- Comparison of 12-Month Visual Outcomes and Patient-Reported Measures between the BVI Isopure Enhanced Monofocal IOL and the AcrySof IQ Monofocal IOL.Korean journal of ophthalmology : KJO · 2026