The Best of Both Worlds: Combining Freehand and Mobile Intraoperative CT-Navigated Instrumentation in Pediatric Deformity Corrections—A Retrospective Case Series of 31 Consecutive Patients
Samuel Friedrich Schaible, Jonathan Simeon Meier, Paul Jan Warnke, Fabian Cedric Aregger, Moritz Caspar Deml
Key points
From the paper's conclusion- Conclusions: The workflow was feasible and safe, with a per-patient radiation dose corresponding to a single scan—about half that of two-scan fully navigated workflows—and high freehand accuracy on intraoperative CT.
Abstract
Background/Objectives: Image guidance improves pedicle screw accuracy in pediatric spinal deformity yet may increase operative time and radiation. We evaluated the feasibility and safety of a single-scan hybrid strategy using freehand screws below the deformity apex and CT-navigated screws at apical and upper thoracic levels. Methods: We retrospectively reviewed 31 patients (24 adolescent idiopathic and 7 syndromic/neuromuscular scoliosis) undergoing posterior instrumentation with intraoperative neuromonitoring (age, 16 ± 5 years; follow-up, 19 ± 10 months). Freehand screws were placed below the apex, followed by one CT to verify them and register navigation; apical/upper thoracic screws were navigated, with alignment assessed by biplanar fluoroscopy. The primary outcome was safety; secondary outcomes were freehand screw accuracy (Gertzbein–Robbins classification), radiation dose, coronal correction, and SRS-22r scores. Results: No neurological or implant-related complications occurred. Of 278 freehand screws, 95.0% were grade A or B; four unacceptable screws (1.4%) were immediately revised with navigation. One of 282 navigated screws (0.4%) was revised after detection on a second intraoperative CT obtained for neuromonitoring changes. Effective dose was 3.80 ± 1.66 mSv per patient. Coronal correction was maintained, and the mean SRS-22r score was 4.2 ± 1.0. Conclusions: The workflow was feasible and safe, with a per-patient radiation dose corresponding to a single scan—about half that of two-scan fully navigated workflows—and high freehand accuracy on intraoperative CT. However, navigated screw accuracy may be overestimated because definitive assessment used fluoroscopy rather than postoperative CT, and the uncontrolled design does not allow conclusions on operative time, warranting prospective comparative studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Augmented reality-enabled image-guided surgical navigation in minimally invasive spine surgery: application beyond screw placement in prone lateral transpsoas interbody fusion-a cadaveric surgical technique study.Journal of spine surgery (Hong Kong) · 2026
- O-arm Navigation-assisted Extreme Lateral Interbody Fusion Utilizing SureTrak Device.Neurologia medico-chirurgica · 2026
- Robotically equipped 3D hybrid operating room in spine and trauma surgery - updated experience in 359 patients and 2080 screws.Journal of robotic surgery · 2026
- The Impact of Image-Guided Screw Placement on Unexpected Return to the Operating Room: A Systematic Review and Meta-Analysis of 91,285 Patients.Global spine journal · 2026
- A Dual-Modal Hybrid Marker for Automatic Registration and Coordinate Hand-Over in C-Arm CT-Guided Spinal Navigation.Sensors (Basel, Switzerland) · 2026
- Modified Jackson Transsacral Rod Fixation With True-CT Navigation for Pediatric High-Grade Dysplastic Spondylolisthesis.Orthopaedics & traumatology, surgery & research : OTSR · 2026