The Impact of Image-Guided Screw Placement on Unexpected Return to the Operating Room: A Systematic Review and Meta-Analysis of 91,285 Patients.
Jaskaran Singh, Marion Sylvain, Mikko Vorster, Bona Baissa, Aazad Abbas, Michael Goytan
Division of Orthopaedic Surgery, University of Manitoba, Winnipeg, MB, Canada. · Faculty of Medicine and Health Sciences, McGill University, Montreal, QC, Canada.
Key points
From the paper's conclusion- This study compares image-guided (navigation and robotics) with freehand screw placement for hardware-related revision, non-hardware reoperation, and URTO following spinal fixation.MethodsA PRISMA-guided systematic review identified comparative studies evaluating image-guided versus freehand screw fixation.
Abstract
Study designSystematic Review and Meta-Analysis.ObjectivesNavigation-guided screw placement improves screw accuracy and may reduce hardware-related revision, yet its effect on overall unexpected return to the operating room (URTO) remains uncertain. This study compares image-guided (navigation and robotics) with freehand screw placement for hardware-related revision, non-hardware reoperation, and URTO following spinal fixation.MethodsA PRISMA-guided systematic review identified comparative studies evaluating image-guided versus freehand screw fixation. Two reviewers performed screening, data extraction, and risk-of-bias assessment. Odds ratios (ORs) were pooled using a random-effects Mantel-Haenszel meta-analysis. Subgroup analyses compared navigated, robotic, and freehand techniques.ResultsTwenty-one studies were included, comprising 91,285 patients (8,743 image-guided; 82,442 freehand). Compared with freehand, image guidance was associated with lower odds of hardware-related revision (OR 0.55, 95% CI 0.40-0.75) and lower odds of URTO (OR 0.69, 95% CI 0.50-0.94), with no difference in non-hardware reoperation (OR 1.03, 95% CI 0.67-1.57). Navigation was associated with lower odds of hardware-related revision (OR 0.51, 95% CI 0.35-0.77) and URTO (OR 0.63, 95% CI 0.51-0.77) versus freehand, whereas robotics showed no significant differences across outcomes. Indirect comparison between navigation and robotics was not statistically significant. Risk of bias was overall high because of retrospective study design, confounding, and inconsistent outcome reporting.ConclusionsNavigation was associated with lower odds of hardware-related revision and lower odds of URTO, without a difference in non-hardware reoperation. Robotics showed no statistically significant advantage over freehand fixation, but its underrepresentation and differing case mix limit comparative conclusions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The Best of Both Worlds: Combining Freehand and Mobile Intraoperative CT-Navigated Instrumentation in Pediatric Deformity Corrections—A Retrospective Case Series of 31 Consecutive PatientsSurgical Techniques Development · 2026
- Navigation Systems Significantly Improve the Efficiency and Safety of CT-Guided InterventionsLife · 2026
- 3D-Printed Guides, Navigation, and Robotic Assistance in Spinal Instrumentation: A Network Meta-Analysis of Pedicle Screw Accuracy and Clinical Outcomes.The spine journal : official journal of the North American Spine Society · 2026
- O-arm Navigation-assisted Extreme Lateral Interbody Fusion Utilizing SureTrak Device.Neurologia medico-chirurgica · 2026
- Robot-assisted versus freehand cannulated-screw fixation for femoral neck fractures: a systematic review of technical, clinical and adoption outcomes.Journal of robotic surgery · 2026
- Axial Convergence in Percutaneous Robotic Pedicle Screw Placement: Mixed-Effects Analysis of 1006 ScrewsSpine Open · 2026