O-arm Navigation-assisted Extreme Lateral Interbody Fusion Utilizing SureTrak Device.
Yasunobu Itoh, Ryo Kitagawa, Ryuzaburo Kanazawa, Yota Zushi, Takao Kono, Shinichi Numazawa, Sadayoshi Watanabe
Department of Neurosurgery, Tokyo General Hospital.
Key points
From the paper's conclusion- The O-arm navigated extreme lateral interbody fusion group demonstrated an 85% reduction in radiation time (11.10 ± 5.44 seconds versus 72.94 ± 17.99 seconds), as well as a 77% decrease in radiation dose (1.50 ± 0.38 versus 6.52 ± 5.30 mGy).
Abstract
Currently, intraoperative guidance during conventional extreme lateral interbody fusion relies primarily on fluoroscopy, which can expose both surgical staff and the patient to radiation. The use of O-arm navigation during extreme lateral interbody fusion and percutaneous pedicle screw fixation is anticipated to enhance accuracy and substantially reduce radiation exposure. To date, there have been no published studies investigating the application of O-arm navigation in extreme lateral interbody fusion procedures. Thirty-three extreme lateral interbody fusion and percutaneous pedicle screw fixation procedures were performed using O-arm navigation in a semi-lateral setup, including 25 single-level and 8 2-level cases. Pathologies included 23 cases of lumbar degenerative spondylolisthesis, 8 canal stenosis, and 2 spondylolytic spondylolisthesis. For each patient, we collated key parameters, including operative time, blood loss, radiation exposure/doses, Japanese Orthopaedic Association score, and Oswestry Disability Index. Patients were placed in a single position. percutaneous pedicle screw fixation was first performed under O-arm guidance; subsequently, disc preparation and cage insertion were navigation-assisted using the SureTrak device. The control group included 33 patients who underwent extreme lateral interbody fusion with C-arm fluoroscopy. Operative time and blood loss were similar between the O-arm navigated extreme lateral interbody fusion and fluoroscopy-guided extreme lateral interbody fusion groups. The O-arm navigated extreme lateral interbody fusion group demonstrated an 85% reduction in radiation time (11.10 ± 5.44 seconds versus 72.94 ± 17.99 seconds), as well as a 77% decrease in radiation dose (1.50 ± 0.38 versus 6.52 ± 5.30 mGy). Both groups showed notable postoperative improvements in Japanese Orthopaedic Association and Oswestry Disability Index scores. Extreme lateral interbody fusion with O-arm navigation demonstrated practicality, reliability, accuracy, and precise cage placement. Enhanced anatomical visualization reduced radiation exposure among surgical personnel.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Augmented reality-enabled image-guided surgical navigation in minimally invasive spine surgery: application beyond screw placement in prone lateral transpsoas interbody fusion-a cadaveric surgical technique study.Journal of spine surgery (Hong Kong) · 2026
- Accuracy of Pedicle Screw Placement at the Cervicothoracic Junction (C7–T2) : A Comparative Study of O-arm Navigation versus C-arm FluoroscopyJournal of Korean Neurosurgical Society · 2026
- The Best of Both Worlds: Combining Freehand and Mobile Intraoperative CT-Navigated Instrumentation in Pediatric Deformity Corrections—A Retrospective Case Series of 31 Consecutive PatientsSurgical Techniques Development · 2026
- Implementation of Intraoperative Cone-Beam CT (Loop-X) in an Established Robotic-Assisted Pedicle Screw Program: An Epoch-Based Cohort StudyJournal of Clinical Medicine · 2026
- Bridging the Markerless Tracking Validation Gap: Intraoperative X-ray Workflow IntegrationarXiv · 2026
- Operator Radiation Dose in C-Arm Fluoroscopy: A Narrative Review of Region- and Procedure-Specific Evidence and a Practical Framework for Intraoperative Dose EstimationSurgeries · 2026