Wavelength Selection for TDLAS Absorption Spectrum Analysis Based on a Spectral Index Estimation
Feng Zhu, Huawei Liu, Wei Wang, Yuhan Jiang, Xilong Yu, Shuangfeng Wang
Key points
From the paper's conclusion- The results show that, when H2 is the target gas, under the two hypothetical conditions, the wavelengths with the highest values of evaluation index are both 2121.834 nm.
Abstract
Selecting the appropriate measurement wavelength is of crucial importance for the implementation of tunable diode laser absorption spectroscopy. For multicomponent gas mixtures, measurement-wavelength selection requires a quantitative assessment of the target-gas absorption response, interference from coexisting species, and local spectral structure under specified operating conditions. To address these issues, this study proposes a comprehensive evaluation index for the measurement wavelength in multicomponent gas mixtures. This index takes into account the detectability of the target gas, the purity of the local spectral area, and the prominence of the absorption peak relative to the background absorption. The measurement wavelengths are directly selected through sorting based on the values of evaluation index. Using the proposed index and method, calculations were conducted for two hypothetical conditions. The results show that, when H2 is the target gas, under the two hypothetical conditions, the wavelengths with the highest values of evaluation index are both 2121.834 nm. Similarly, the wavelengths of the highest values of evaluation index of O2 are both 760.654 nm, while the highest values of evaluation index of CO2 are significantly higher than the above two gases, which respectively correspond to 16,711.174 nm and 2020.522 nm. In addition, when CO2 is the target gas, there are a large number of high-value wavelengths above 98, indicating that CO2 has stronger absorption and more absorption spectral lines, which is also consistent with the selection of different measurement wavelengths in the literature. Furthermore, calculations were also conducted under three conditions referenced from previous literature. The quantitative evaluation results of the selected wavelengths in the literature are also consistent with the above conclusions. The proposed evaluation index and calculation method, through quantitative evaluation to select wavelengths, can provide a repeatable basis and explicit combination of local spectral purity and target-peak contrast for the selection of laser sources and design for tunable diode laser absorption spectroscopy experiments.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Multi-Component Broadband Absorbers Detection via Wavelength Modulation Spectroscopy: First Harmonic Signal Analysis and Processing.Analytical chemistry · 2026
- Full-range CO2 detection using dual-path WMS-DAS and multi-regime adaptive fusion.Optics letters · 2026
- TDLAS Spectral Line Identification and Quantification Based on Hill-Climbing Algorithm with Progressive Window ExpansionPhotonics · 2026
- Highly Sensitive CH4/C2H2 Dual-Component TDLAS Sensor Based on a Dual-Channel Hexagram Multi-Pass CellSensors · 2026
- Influence of key operational parameters on harmonic signals in WMS-TDLAS: a simulation study.Applied optics · 2026
- Simplified Calibration and Laser Nonlinearity Error Analysis for Peak-Locking TDLAS SystemsPhotonics · 2026