Full-range CO2 detection using dual-path WMS-DAS and multi-regime adaptive fusion.
Chuan Li, Jie Wang, Ruifeng Wang, Guishi Wang, Xuezhe Xu, Xiaoming Gao, Kun Liu
Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China. · Anhui Landun Photoelectron Co., Ltd., Hefei 244000, China.
Key points
From the paper's conclusion- Here, we propose a TDLAS-based method for full-dynamic-range CO 2 detection.
Abstract
Tunable diode laser absorption spectroscopy (TDLAS) offers high sensitivity, selectivity, robustness, and real-time detection. However, most TDLAS-based sensors have a limited dynamic range, typically below 104. Here, we propose a TDLAS-based method for full-dynamic-range CO2 detection. A dual-path absorption cell is combined with a wavelength modulation spectroscopy-direct absorption spectroscopy (WMS-DAS) measurement strategy to realize full-range detection. A dual-logistic adaptive weighting algorithm is developed to fuse adjacent channels and suppress range-boundary discontinuities, enabling smooth and continuous transitions across adjacent detection regimes without hard switching. Experiments demonstrate that the proposed configuration and detection scheme enable CO2 measurements from sub-ppm levels to 100% concentration, with a dynamic range of 3.3 × 106, while achieving a 1σ detection limit of 0.3 ppm at an integration time of 72 s. The proposed method shows strong potential for applications ranging from trace-level environmental monitoring to industrial gas purity analysis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Mid-infrared heterodyne phase-sensitive dispersion spectroscopy for simultaneous CO2 and N2O measurement over broad concentration ranges.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026
- Multi-Component Broadband Absorbers Detection via Wavelength Modulation Spectroscopy: First Harmonic Signal Analysis and Processing.Analytical chemistry · 2026
- EXPRESS: Development of dynamic time-over-threshold method for signal processing in cavity ring-down spectroscopy.Applied spectroscopy · 2026
- Effective wavenumber coordinate correction and CO2 concentration retrieval constrained by an absorption-band prior.The Analyst · 2026
- Ultra-Wide-Range Online Monitoring of Carbon Dioxide Based on a Dual-QTF Photoacoustic Spectroscopy SensorAnalytical Chemistry · 2026
- Deep Learning-Enhanced Dual-Component Gas Sensor Based on Wavelength Modulation SpectroscopyAnalytical Chemistry · 2025