Multi-Component Broadband Absorbers Detection via Wavelength Modulation Spectroscopy: First Harmonic Signal Analysis and Processing.
Rui Wang, Liqun Sun, Linbo Tian, Luying Yi
State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instruments, Tsinghua University, Beijing100084, China. · Department of Biomedical Engineering, College of Future Technology, Peking University, Beijing100871, China.
Key points
From the paper's conclusion- In this paper, we propose a new WMS approach based on first harmonic (1f) signal analysis and processing for simultaneous detection of multiple broadband absorbers.
Abstract
Measuring broadband absorbers remains a challenging task for tunable diode laser absorption spectroscopy (TDLAS), and the simultaneous quantification of multi-component mixtures further complicates such measurements due to overlapping absorption spectra and inter-species interference. In this paper, we propose a new WMS approach based on first harmonic (1f) signal analysis and processing for simultaneous detection of multiple broadband absorbers. By applying a logarithmic transformation to the transmitted intensity, the demodulated 1f component becomes linear in absorbance and thus does not rely on the absorption line shape, which allows for the retrieval of broadband absorbers concentration by measuring 1f signal. A reference gas featuring a narrow absorption line within the absorption band of the broadband absorbers is introduced for wavelength localization, using the peak of its second harmonic (2f) signal as the wavelength marker. Furthermore, we develop a four-point elimination scheme to suppress error amplification in multi-gas measurements. In a proof-of-concept experiment, we selected ethanol (C2H6O) and isobutane (C4H10) as broadband absorbers and ethane (C2H6) as reference gas. Accurate retrieval is achieved under varying C2H6 backgrounds (15, 25, 35, 45, and 55 ppm), with the measured C2H6O and C4H10 concentrations remaining close to their nominal values and a maximum relative error below 2.5%. Continuous measurements yield 1σ precisions of 2.71 ppm (C2H6O) and 2.81 ppm (C4H10), while Allan-deviation analysis provides detection limits of 116 ppb at 6.4 s and 158 ppb at 6.3 s, respectively. This method enables simple, effective, and simultaneous high-precision sensing of multiple broadband absorbers without detailed line-shape modeling, and can be readily extendable to other broadband multi-gas applications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Full-range CO2 detection using dual-path WMS-DAS and multi-regime adaptive fusion.Optics letters · 2026
- Influence of key operational parameters on harmonic signals in WMS-TDLAS: a simulation study.Applied optics · 2026
- Wavelength Selection for TDLAS Absorption Spectrum Analysis Based on a Spectral Index EstimationSensors · 2026
- Research on Spectral Baseline Reconstruction of Broad-Spectrum Absorption Characteristics for Alkanes Mixture Gases Based on Laser Absorption SpectroscopyAnalytical Chemistry · 2025
- Absolute measuring interferometric high-speed profilometer using wavelength modulation at ultrasonic frequenciesMeasurement Science and Technology · 2026
- CH₄ concentration prediction in WMS-TDLAS systems using 2f/1f signal and CNN.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026