From the paper's conclusion- To address this issue, this paper proposes an approach for gas characteristic spectral line extraction and quantitative analysis based on the hill-climbing algorithm with progressive window expansion.
Abstract
The field application environment of TDLAS gas sensors is inherently complex, and the acquired spectral signals are frequently contaminated by interfering backgrounds. Such interferences compromise the measurement accuracy of gas concentration. To address this issue, this paper proposes an approach for gas characteristic spectral line extraction and quantitative analysis based on the hill-climbing algorithm with progressive window expansion. In this approach, the full measurement range of the TDLAS sensor is divided into segments, and the characteristic spectral line parameters corresponding to a known concentration are pre-stored in each segment. The proposed hill-climbing algorithm with progressive window expansion is then employed to estimate the spectral parameters. In the comparative experiments, using the same TDLAS sensor subject to nonlinear laser drift and a contaminated gas cell, the proposed method and the existing traditional method were respectively employed to process the same raw spectral data acquired by the sensor and to detect the same batch of methane gases at different concentrations. Compared with the traditional method, the proposed method improves the fitting correlation coefficient of spectral background prediction from 0.9985 to 0.9997, and enables more accurate gas concentration prediction simultaneously while extracting the gas characteristic absorption lines. The prediction errors of the proposed method for all concentrations fall within the allowable error limits for methane sensors in Chinese coal mines (i.e., absolute error ≤ 0.05% for the 0–1% range, and relative error ≤ 5% of the actual value for the 1–100% range). In the 6 h detection of the 0.05% methane gas sample, according to the statistics, the average detection value of the proposed method is 0.0491%, which is very close to the true detection value of 0.05%, and the detection variance is only 0.0124%. The comparative experimental results show that the proposed method can successfully extract the gas characteristic lines from raw spectral signals contaminated by interfering backgrounds, while achieving accurate concentration prediction, and its concentration prediction error is significantly lower than that of the conventional method. The proposed method enriches the technical arsenal for spectral signal analysis in TDLAS gas sensors, offers a valuable reference for designing spectral analysis strategies when such sensors are deployed in industrial field applications, and contributes, to a certain extent, to enhancing the sensor’s reliability and stability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Intelligent Algorithm-Assisted Indirect Absorption Spectroscopy for Trace Gas SensingSensors · 2026
- Wavelength Selection for TDLAS Absorption Spectrum Analysis Based on a Spectral Index EstimationSensors · 2026
- Gas Sensing Based on Heterodyne Mach-Zehnder Interferometric Phase-Dispersion Spectroscopy.Analytical chemistry · 2026
- Physics-guided spectral attention for baseline-free concentration regression from laser absorption spectra.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026
- A Single-Laser TDLAS Sensor with Dual-Gas Modulation and BiLSTM-Based Spectral Decoupling for CH₄ /C₂ H₆ DetectionAnalytical Chemistry · 2026
- Baseline-Free Wide-Range Methane Concentration Measurement Based on Logarithmic Second Derivative Spectroscopy.Analytical chemistry · 2026