Evaluation of the Effect of Extracerebral Layers in Cerebral Photoplethysmography (PPG) Using a Head Phantom.
Karina Awad-Pérez, Maria Roldan, Panicos A Kyriacou
Research Centre for Biomedical Engineering, City St George's University of London, London EC1V 0HB, UK. · Crainio Limited, London EC3V 9DU, UK.
Key points
From the paper's conclusion- These findings have clinical implications and highlight the need for mitigation strategies that account for extracerebral contributions in brain optical monitoring techniques.
Abstract
Optical brain monitoring techniques such as near-infrared spectroscopy (NIRS) and cerebral photoplethysmography (PPG) are promising non-invasive approaches for cerebral haemodynamic assessment; however, the measured signal can reflect contributions from both cerebral and extracerebral circulation. This study investigated the effect of extracerebral layers on forehead PPG signals using a multilayer head phantom with independent control of scalp and cerebral perfusion. Three perfusion conditions were performed: both layers perfused, scalp occlusion, and brain occlusion. PPG signals were acquired at 770, 810, and 880 nm using a custom optical probe with proximal (10 mm) and distal (30 mm) source-detector separations. Signal features were extracted and compared across conditions. Scalp occlusion produced a strong reduction in pulsatile signal, with complete signal collapse at the proximal detector. A small pulsatile signal (~5% of baseline amplitude) was detected at the distal detector, indicating that longer source-detector separations (30 mm) can detect signals originating from the brain phantom. Brain occlusion resulted in a partial amplitude reduction (~45%) with preserved waveform morphology across all wavelengths. While this demonstrates that cerebral perfusion changes are detectable in the presence of intact extracerebral circulation, it also highlights a potential masking effect as scalp circulation alone can produce a good-quality PPG signal despite complete cerebral hypoperfusion. These findings have clinical implications and highlight the need for mitigation strategies that account for extracerebral contributions in brain optical monitoring techniques.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development and optical characterization of a multilayered head phantom for optical brain monitoring.Journal of biomedical optics · 2026
- Missed isochromatic cardiac pulsation in remote photoplethysmography: detection, impact, and removalBiomedical Optics Express · 2026
- Cross-polarised temple photoplethysmography for motion-robust and equitable cardiovascular sensing in virtual reality.Biomedical optics express · 2026
- Hyperspectral imaging photoplethysmography: insights into the signals' origin and usage.Biomedical optics express · 2026
- NIRSLINK: A Modular Cascaded Wearable Near-Infrared Spectroscopy System for High-Speed Multi-Site Hemodynamic Monitoring.Biosensors · 2026
- Development of a Novel Non-Invasive Blood Pressure Measurement Technique Using Near-Infrared Spectroscopy and Deep Neural NetworksBiomedical Physics & Engineering Express · 2026