Cross-polarised temple photoplethysmography for motion-robust and equitable cardiovascular sensing in virtual reality.
Alya Alshehhi, Amine El Moutaouakil, Qammer H Abbasi, Rami Ghannam
James Watt School of Engineering, University of Glasgow, Glasgow, UK. · Department of Electrical and Communication Engineering, College of Engineering, United Arab Emirates University, Al Ain, United Arab Emirates.
Key points
From the paper's conclusion- We evaluated near-infrared cross-polarised temple PPG in 22 participants during free head movement in VR, using simultaneous ECG and three-axis acceleration as references.
Abstract
Virtual reality (VR) increasingly relies on continuous physiological signals, such as heart rate and heart-rate variability, to monitor users' state in real time. The face is well suited to capturing these signals: the temple lies over a superficial artery, making it a strong photoplethysmography (PPG) site, but head motion and skin pigmentation can degrade optical cardiovascular measurements. We evaluated near-infrared cross-polarised temple PPG in 22 participants during free head movement in VR, using simultaneous ECG and three-axis acceleration as references. Orthogonal polarisers on the emitter and detector suppressed superficial reflections while preserving pulsatile light. Compared with unpolarised PPG, cross-polarisation was associated with a 29% reduction in the relative standard deviation of the DC baseline, a reduction in heart-rate bias from 1.84 to 0.01 bpm, and lower RMSSD and SDNN errors (43% and 44%). The largest HRV gains were observed in medium and darker skin groups. These results provide preliminary evidence that cross-polarisation may improve both the accuracy and the cross-skin-tone consistency of head-mounted PPG, thus supporting its use in next-generation smart eyewear and extended-reality devices.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Missed isochromatic cardiac pulsation in remote photoplethysmography: detection, impact, and removalBiomedical Optics Express · 2026
- Estimating heart rate variability using facial video photoplethysmography: a pilot validation studyScientific Reports · 2026
- Contactless camera-based estimation of heart rate and variability from short facial video using remote photoplethysmography, remote ballistocardiography, and quality-aware selectionEuropean Heart Journal · 2026
- Reliable wrist PPG monitoring by mitigating poor skin sensor contactScientific Reports · 2025
- Contactless Vital Sign Monitoring in Emergency Settings: A Factorial Study of Camera Position and Motion Using rPPGAlgorithms · 2026
- Accuracy of Photoplethysmography-Derived Pulse Rate Variability Compared with Electrocardiography-Derived Heart Rate Variability: A Systematic Review and Meta-Analysis.Sensors (Basel, Switzerland) · 2026