Development of a Novel Non-Invasive Blood Pressure Measurement Technique Using Near-Infrared Spectroscopy and Deep Neural Networks
Roya Kheyrkhah Shali, Seyed Kamaledin Setarehdan, Behjat Seifi
University of Tehran · Tehran University of Medical Sciences
Key points
From the paper's conclusion- The results demonstrate that prefrontal NIRS combined with deep learning provides a reliable and accurate framework for non-invasive blood pressure change monitoring.
Abstract
Non-invasive monitoring of blood pressure is essential for health management in daily life, particularly for elderly individuals and patients with autonomic dysfunction. However, conventional cuff-based sphygmomanometers are uncomfortable and provide discontinuous monitoring. In this study, we propose a novel non-invasive technique for blood pressure change assessment based on prefrontal near-infrared spectroscopy (NIRS) and deep neural networks. Unlike existing approaches that rely primarily on electrocardiography or photoplethysmography signals, the proposed method independently utilizes prefrontal NIRS signals to capture optical responses associated with postural changes. This enables early prediction of blood pressure changes following standing. NIRS is a non-invasive, real-time, portable, high temporal resolution, and cost-effective in comparison with other brain monitoring modalities. NIRS signals were collected from 40 healthy adults (aged 19-39 years) as test and training groups, 40 entirely new volunteers as an independent evaluation group, and during sit-to-stand transitions using a two-channel system, while reference blood pressure measurements were obtained using an automatic sphygmomanometer. An adaptive filtering framework was applied to suppress physiological noise, and multiple deep learning architectures were evaluated for regression analysis. A hybrid convolutional neural network-gated recurrent unit (CNN-GRU) model achieved the best performance, yielding root mean square errors of 1.95 mmHg and 1.75 mmHg for systolic and diastolic blood pressure, respectively. The results demonstrate that prefrontal NIRS combined with deep learning provides a reliable and accurate framework for non-invasive blood pressure change monitoring. This technique shows strong potential for wearable applications in elderly populations and individuals at risk of orthostatic hypotension, and it establishes a foundation for future clinical deployment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Continuous Cuffless Blood Pressure Estimation Using PPG From Methods to Clinical TranslationarXiv · 2026
- Skin tone and diagnostic equity in contactless blood pressure screening: a prospective observational field evaluation of remote photoplethysmography in NigeriaBMJ Open · 2026
- A Dual-Output Physiology-Informed Neural Network Architecture for Continuous Cuffless Blood Pressure Waveform Estimation: A Proof‑of‑ConceptArtery Research · 2026
- Artificial Intelligence Enabled Diagnostics Using Photoplethysmography (PPG): Beyond SpO2 and Heart Rate.Life (Basel, Switzerland) · 2026
- A Scoping Review of Deep Learning Methods for Photoplethysmography Data.Health data science · 2026
- Dual-Path Cuffless PPG-Based Blood Pressure Estimation Using Conformer & Swin TransformerIEEE Journal of Biomedical and Health Informatics · 2025