A VHF-Voltage Double Time Integral Method for Apparent-Charge Estimation of Partial Discharge in Gas-Insulated Switchgear.
Subin Gao, Xiaoli Zhou, Chao Pan, Yong Qian, Gehao Sheng
College of Intelligent Robotics and Advanced Manufacturing, Fudan University, Shanghai 200433, China. · School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.
Key points
From the paper's conclusion- The results support the feasibility of calibrated DTIV estimation for the tested sensor and ideal laboratory configuration.
Abstract
Gas-insulated switchgear (GIS) is widely used in modern power systems, but transportation, installation, and manufacturing defects can trigger partial discharge (PD). Apparent charge is a key indicator of PD intensity and insulation deterioration, yet conventional pulse current measurements perform poorly in field environments because of interference, pulse superposition, non-flat sensor responses, and impedance mismatch. Very-high-frequency (VHF) sensing is sensitive to on-site PD but lacks a direct quantitative mapping to apparent charge. This study derives and optimizes a double time integral of voltage (DTIV) method for capacitively coupled VHF sensors. Simulation and experimental platforms were established, and through-origin linear regression was used to relate DTIV output to reference apparent charge. The first and second voltage zero-crossings (ZC1 and ZC2) were evaluated as integration upper limits, and the preferred DTIV_ZC2 strategy was further assessed using thresholds of 1% and 5% of the signal peak. For the simulated library, using the second zero-crossing increased the coefficient of determination from 0.8957 to 0.9585 and reduced the average relative error to 4.5%. A 5% threshold further improved these values to 0.9641 and 3.9%, respectively. The results support the feasibility of calibrated DTIV estimation for the tested sensor and ideal laboratory configuration.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Review of Insulation Defect Detection Methods for a Gas-Insulated SwitchgearEnergies · 2026
- A Study on a Digital Twin Method for Modelling the Diffusion Process of Fault Gases Inside High-Voltage Switchgear Combining Virtual and Physical Models.Sensors (Basel, Switzerland) · 2026
- Investigation on Electromagnetic–Thermal–Mechanical Multi-Physics Field Characteristics of GIS Disconnector Under Different Contact ConditionsEnergies · 2026
- Benchmarking of Multi-Modal Partial Discharge Sensors and a Cross-Modal Corroboration Framework for Noise Discrimination in Air-Insulated Medium-Voltage Metal-Clad Switchgear.Sensors (Basel, Switzerland) · 2026
- A Virtual–Physical Sensing Method for Fault-Gas Source Localization in High-Voltage SwitchgearEnergies · 2026
- Bypass Sheath Voltage Limiters at Cable-to-GIS Terminations: Geometry-Resolved Connection-Lead Impedance for Insulation Coordination Under Very Fast Transient OvervoltagesEnergies · 2026