A Study on a Digital Twin Method for Modelling the Diffusion Process of Fault Gases Inside High-Voltage Switchgear Combining Virtual and Physical Models.
Xin Wang, Hao Luo
Guoneng Guangtou Beihai Power Generation Co., Ltd., Beihai 536017, China. · State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing 400044, China.
Key points
From the paper's conclusion- The maximum error in concentration balance was within 10 percent, providing a theoretical basis and engineering reference for the optimised placement of gas sensors in high-voltage switchgear and for fault tracing and localisation.
Abstract
Monitoring gas generated by internal faults in high-voltage switchgear is crucial for early warning and condition assessment; however, the diffusion process between gas generation and detection is currently widely overlooked, which severely compromises the accuracy of gas-based assessments. Implementing "virtual sensing" for high-voltage switchgear using digital twin technology to supplement data from physical sensors can effectively support digitalised and intelligent operation and maintenance. To this end, taking the characteristic gases of partial discharge as the subject of study, we first constructed a 1:1 scale digital twin model of internal gas diffusion within a 10 kV high-voltage switchgear. Calculations revealed significant differences in the diffusion processes of various gases: CO diffuses rapidly and mixes strongly, making it suitable for early warning; CO2 and O3 tend to accumulate in lower regions and stagnant zones, making them sensitive to faults in the lower sections; whilst NO reflects the channelling effect within the structure. Subsequently, a test platform comprising a 10 kV high-voltage switchgear unit and a gas detector was established for experimental validation. This revealed the trends in gas concentration changes, response sequences and peak behaviour at different fault locations, thereby verifying the validity of the proposed model. The maximum error in concentration balance was within 10 percent, providing a theoretical basis and engineering reference for the optimised placement of gas sensors in high-voltage switchgear and for fault tracing and localisation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Virtual–Physical Sensing Method for Fault-Gas Source Localization in High-Voltage SwitchgearEnergies · 2026
- Coupled Multi-Physics Study on SF6 Decomposition Gas Diffusion and Sensor Placement Optimization in GIS Busbars.Sensors (Basel, Switzerland) · 2026
- Research on digital twin diagnosis model for the thermal-electric field of high-voltage switchgearsScientific Reports · 2025
- GIS gas-component detection based on a WGM gas-sensing microcavity and a one-dimensional convolutional neural networkJournal of Engineering and Applied Science · 2026
- Digital twin-driven fault diagnosis of power substations by multi-modal fusion learningNature Communications · 2026
- Rapid Response Strategy for Transformer Gas Relay Fault Diagnosis Assisted by the IDBO-VMD-SVM Combined ModelProcesses · 2026