A Virtual–Physical Sensing Method for Fault-Gas Source Localization in High-Voltage Switchgear
Yujian Zhou, Hao Luo
Key points
From the paper's conclusion- The results showed that the reported relative errors in final recorded concentrations did not exceed 9.09%; MP8, MP1, and MP2 were the three highest-ranked monitoring locations; under five-fold stratified cross-validation, the accuracy, macro-precision, macro-recall, and macro-F1 score of the random forest model all reached 100%.
Abstract
Characteristic gas monitoring is an important approach for detecting incipient faults and supporting the intelligent operation and maintenance of high-voltage switchgear. However, existing methods primarily rely on concentration thresholds or steady-state features, making it difficult to simultaneously optimize sensor placement and accurately localize fault-gas sources. To address these limitations, this study proposes a virtual–physical sensing method for fault-gas source localization. A full-scale test platform and a 1:1 three-dimensional numerical model of 10 kV air-insulated switchgear (AIS) were constructed to obtain the time-series responses of CO, CO2, NO, and O3 for different fault-gas source locations. Candidate monitoring points were quantitatively evaluated using a combination of the Welch t-test, mutual information, and entropy difference. Multi-gas features from the selected monitoring points were then fused to identify nine fault-location classes. The results showed that the reported relative errors in final recorded concentrations did not exceed 9.09%; MP8, MP1, and MP2 were the three highest-ranked monitoring locations; under five-fold stratified cross-validation, the accuracy, macro-precision, macro-recall, and macro-F1 score of the random forest model all reached 100%. The proposed method provides a quantitative basis for reducing the number of gas sensors and localizing fault-gas sources in high-voltage switchgear.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Study on a Digital Twin Method for Modelling the Diffusion Process of Fault Gases Inside High-Voltage Switchgear Combining Virtual and Physical Models.Sensors (Basel, Switzerland) · 2026
- Coupled Multi-Physics Study on SF6 Decomposition Gas Diffusion and Sensor Placement Optimization in GIS Busbars.Sensors (Basel, Switzerland) · 2026
- GIS gas-component detection based on a WGM gas-sensing microcavity and a one-dimensional convolutional neural networkJournal of Engineering and Applied Science · 2026
- Review of Insulation Defect Detection Methods for a Gas-Insulated SwitchgearEnergies · 2026
- Research on digital twin diagnosis model for the thermal-electric field of high-voltage switchgearsScientific Reports · 2025
- Detecting Decomposition Gases from Gas-Insulated Switchgear with Cavity-Enhanced Polarization-Differential Raman SpectroscopyAnalytical Chemistry · 2026