Developing the Readout Electronics for a Custom 64 × 64 SPAD Array: From Single-Board Prototyping to FPGA Implementation Toward Stellar Intensity Interferometry.
Álvaro Quintana, Guillermo González-de-Rivera, Sergio López-Buedo, Francisco Prada
Hardware and Control Technology Laboratory (HCTLab), Universidad Autónoma de Madrid, 28049 Madrid, Spain. · High Performance Computing and Networking (HPCN), Universidad Autónoma de Madrid, 28049 Madrid, Spain.
Key points
From the paper's conclusion- This work presents a modular, event-driven acquisition system for a 64 × 64 SPAD array within the La Palma Quantum Interferometer (LPQI) project, repurposing a LiDAR detector for multi-telescope interferometry.
Abstract
Single-photon avalanche diode (SPAD) arrays enable photon-starved applications, including time-of-flight imaging and stellar intensity interferometry. Their astronomical use remains scarcely explored, as the bottleneck is usually not detection but rather acquisition electronics for high-rate event streams. This work presents a modular, event-driven acquisition system for a 64 × 64 SPAD array within the La Palma Quantum Interferometer (LPQI) project, repurposing a LiDAR detector for multi-telescope interferometry. Two stages are used: a Raspberry Pi 5 with a custom board for validation, and an AMD Kria KR260 (Zynq UltraScale+ MPSoC) implementing the Address-Event Representation (AER) handshake in hardware at 100 MHz. The system streams AER events without per-event timestamping; sub-nanosecond time-tagging is left for a future stage based on the White Rabbit protocol. Optical bench tests confirmed spatial detection and localization of photons at a measured throughput of up to ≈124 keps under the highest illumination condition tested, and dark-count-rate characterization showed a rate below 10 Hz for most pixels (median: 1.68 Hz at 27.8 °C); raw per-pixel event-count maps further confirmed, for the first time on this array, the expected 2 × 2 spatial pattern of inter-pixel crosstalk from its shared-cathode pixel groups. The results demonstrate the feasibility of repurposing a LiDAR SPAD sensor and establish an acquisition-electronics baseline to aid the development of a timestamped, multi-telescope system for deployment on five telescopes of the Roque de los Muchachos Observatory.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Optical ISAC with Single-Photon Avalanche Diode (SPAD) ArraysarXiv · 2026
- A Practical Calibration Method for Correcting Count-Rate Nonlinearity in Free-Running Silicon SPADsPhotonics · 2026
- An innovative SPICE crosstalk compact model for SPAD arrays based on TCAD simulation verificationEngineering Research Express · 2026
- Characterization of a 3-D stacked CMOS SPAD depth sensor in 45/22-nm technologyOptics Express · 2026
- Count-nonlinearity correction of single-photon avalanche diodes using laser superposition and reference-photon-rate validationMeasurement Science and Technology · 2026
- Self-Referenced Diagnosis of SPAD Dark-Count-Rate Switching for Quantum Communication ReceiversarXiv · 2026