A Practical Calibration Method for Correcting Count-Rate Nonlinearity in Free-Running Silicon SPADs
Youbo Hu, Lin Yin, Dongyan Nie, Shubin Yan
Key points
From the paper's conclusion- It therefore provides a practical calibration route for commercial free-running silicon SPAD modules that require rapid on-site nonlinearity correction over a wide dynamic range.
Abstract
Single-photon avalanche diodes (SPADs) operated in free-running mode exhibit three major nonideal effects: dead time, recovery time, and afterpulsing. Together, these effects cause the measured count rate to deviate from the true incident photon rate, degrade photon counting accuracy, and limit the linear dynamic range of the detector. Here, we establish a joint correction model for dead time, recovery time, and afterpulsing, based on a nonhomogeneous Poisson process, and propose a staged decoupling calibration strategy spanning from low to high count rates to systematically extract the afterpulse probability, dead time, and recovery-time constant. The proposed model is benchmarked on a commercial silicon SPAD module. Over a dynamic range of 550 kHz to 30 MHz, the mean absolute percentage error (MAPE) between model predictions and factory-provided correction factors is 2.74%, with a coefficient of determination (R2) of 0.985; relative deviations remain within 3% at low and moderate count rates. The proposed scheme requires only a continuous wave (CW) light source and a single channel TDC, eliminating the need for pulsed sources and external gated synchronization. It therefore provides a practical calibration route for commercial free-running silicon SPAD modules that require rapid on-site nonlinearity correction over a wide dynamic range. The demonstration and benchmark are performed on one commercial module, and extension to other low-afterpulse silicon SPADs is expected after local calibration and verification of the afterpulse-template separability conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Count-nonlinearity correction of single-photon avalanche diodes using laser superposition and reference-photon-rate validationMeasurement Science and Technology · 2026
- Self-Referenced Diagnosis of SPAD Dark-Count-Rate Switching for Quantum Communication ReceiversarXiv · 2026
- Uncooled Photon‐Counting Detectors: From PMTs to CMOS‐Integrated and Emerging SPAD TechnologiesLaser & Photonics Reviews · 2026
- An innovative SPICE crosstalk compact model for SPAD arrays based on TCAD simulation verificationEngineering Research Express · 2026
- A Fully Circular P+/N-Well CMOS Diode with Low Dark Count Rate for Single-Photon Imaging.Sensors (Basel, Switzerland) · 2026
- Fast SPAD-array timing-error correction with time-referencing for non-line-of-sight imaging.Optics express · 2026