Soft Clipping: An Often-Overlooked Non-Linear Amplitude Response of IEPE/ICP Piezoelectric Sensors.
Oliver M Zobel, Johannes Maierhofer, Michael Kreutz, Daniel J Rixen
Chair of Applied Mechanics, TUM School of Engineering and Design, Technical University of Munich, Boltzmannstr. 15, 85748 Garching, Germany.
Key points
From the paper's conclusion- Overall, the findings emphasize that avoiding operation outside the rated measurement range and implementing appropriate monitoring or warning strategies are essential for reliable IEPE/ICP measurements, especially for time-domain analysis methods.
Abstract
This article reviews soft clipping, a non-linear amplitude response of IEPE/ICP sensors, which occurs when the internal electronics of an IEPE/ICP sensor exceed their specified linear operating range, typically corresponding to an output of ±5 V. Because most measurement systems allow a wider voltage range of ±10 V, this non-linear behavior can occur without triggering system-level warnings. Shaker tests indicate that prolonged operation beyond the rated measurement range results in significant signal distortion, particularly attenuating negative acceleration values and producing asymmetric signals. Even after returning to nominal operating conditions, a recovery time of several seconds is required. While the soft clipping effect appears largely frequency independent up to 5 kHz, it may be difficult to detect in real-world vibration tests with complex, broadband signals. Impact tests further reveal that soft clipping subtly affects shock responses, primarily altering initial peaks and potentially obscuring high-frequency modes that decay rapidly. In contrast, frequency-domain analyses are less affected. Overall, the findings emphasize that avoiding operation outside the rated measurement range and implementing appropriate monitoring or warning strategies are essential for reliable IEPE/ICP measurements, especially for time-domain analysis methods.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Design of a low-distortion IEPE signal conditioning circuit for shock wave measurementJournal of Physics: Conference Series · 2026
- A comprehensive evaluation of an inertial sensor for High-Intensity shocks and vibration analysis in a real tennis contextMeasurement · 2026
- Electrical Response of PVDF Piezoelectric Sensors to Controlled Low-Energy Impacts: Influence of Geometry and Mounting Conditions.Sensors (Basel, Switzerland) · 2026
- A System Response-Based Inversion Framework for Impact Pressure Measurement Using PVDF Sensors.Sensors (Basel, Switzerland) · 2026
- Field and Numerical Investigation of Impact-Echo Responses for Internal Defect Assessment in Cylindrical Concrete Bridge PiersBuildings · 2026
- Effect of transducer scanning velocity during extended field of view imaging acquisition on pennate and fusiform muscles echo intensity.Journal of ultrasound · 2026