Journal of Physics: Conference Series

Design of a low-distortion IEPE signal conditioning circuit for shock wave measurement

Hui Lv, Wangrui Zhao, Qinghua Lin

Key points

From the paper's conclusion
  • To meet the high-fidelity acquisition requirement in shock wave measurement, a low-distortion IEPE signal conditioning circuit is designed.

Abstract

To meet the high-fidelity acquisition requirement in shock wave measurement, a low-distortion IEPE signal conditioning circuit is designed. To alleviate the engineering trade-off between high dynamic input impedance and high-temperature baseline drift, a T-type AC bootstrapping topology is adopted to increase the AC equivalent input impedance while stabilizing the DC bias. Simulation and test results show that the intrinsic bandwidth of the front-end core circuit exceeds 1 MHz, providing sufficient bandwidth margin for the effective measurement frequency band, and the nonlinear error is approximately 0.7%, meeting the requirements for shock wave overpressure measurement circuits. With a streamlined and practical hardware architecture, the proposed design achieves excellent transient tracking and stable output, providing a reliable instrumentation front-end solution for high-dynamic overpressure measurement in complex explosion fields.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers