Electrical Response of PVDF Piezoelectric Sensors to Controlled Low-Energy Impacts: Influence of Geometry and Mounting Conditions.
Jan Szymenderski, Łukasz Gierz, Grzegorz Ślaski, Sławomir Sowa
Division of Theoretical and Applied Electrical Engineering, Institute of Electrical Engineering and Electronics, Faculty of Control, Robotics and Electrical Engineering, Poznań University of Technology, 60-965 Poznań, Poland. · Institute of Machine Design, Faculty of Mechanical Engineering, Poznań University of Technology, 60-965 Poznań, Poland.
Key points
From the paper's conclusion- This laboratory study quantifies how the geometry and mounting conditions of polyvinylidene fluoride (PVDF) film sensors influence two design metrics of their electrical response to repeatable controlled low-energy impacts: the peak-to-peak voltage, Upp, which governs detection-threshold robustness, and the ring-down duration, td, which limits event separability.
Abstract
Contact-based impact sensing is a candidate alternative to optical seed monitoring near the seed-tube outlet, where dust contamination limits optical sensors. This laboratory study quantifies how the geometry and mounting conditions of polyvinylidene fluoride (PVDF) film sensors influence two design metrics of their electrical response to repeatable controlled low-energy impacts: the peak-to-peak voltage, Upp, which governs detection-threshold robustness, and the ring-down duration, td, which limits event separability. Impacts were generated with a patented spring-driven test stand; a separate high-speed-video validation at four spring settings showed that the pre-impact kinetic energy of the impactor was repeatable to within approximately 5% (relative standard deviation). Five commercial PVDF sensors were first compared in a beam configuration (Stage I); two of them were then tested in 21 and 5 mounting variants, respectively (Stage II); and three selected configurations were characterised over nominal impact energies of 0.64-25.5 mJ (Stage III). For a single sensor, the mounting alone changed Upp from 2.6 to 22 V and td from 2.2 to 360 ms, and a foam damper shortened td by a factor of 1.6-25. In Stage III, the dependence of Upp on the nominal spring energy was described by a square-root model with an intercept (R2=0.975-0.981). The ring-down duration did not exceed 13.1 ms in the tested configurations, remaining below the assumed minimum inter-impact interval of 100 ms. Field performance, clogging detection and counting accuracy were not evaluated and are left for future work.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A System Response-Based Inversion Framework for Impact Pressure Measurement Using PVDF Sensors.Sensors (Basel, Switzerland) · 2026
- A Corrugated PVDF-Based Flexible Piezoelectric Sensor for Physiological Signal DetectionACS Sensors · 2026
- Precise Measurement of Piezoelectric Response With Interferometric Piezoresponse Force Microscopy.Small methods · 2026
- Thousandfold Boosting Peak Power Output in Piezoelectric Nanogenerator via Impact Excitation StrategyAdvanced Energy Materials · 2025
- Biogenic SiO2-induced β-phase engineering in electrospun PVDF nanofibers for self-powered, sub-millisecond impact sensing.Nanoscale · 2026
- Thermal Shock Effects on PZT Piezoelectric Pressure Sensors for Blast Pressure Measurement.Micromachines · 2026