Electrochemical Evaluation of Polymer-Based Microelectrode Arrays: Analytical Performance on Oxygen and Hydrogen Peroxide.
Eliana Fernandes, Ana Ledo, Kee Scholten, Ellis Meng, Greg A Gerhardt, Rui M Barbosa
Faculty of Pharmacy, University of Coimbra, Health Science Campus, Azinhaga de Santa Comba, 3000-548 Coimbra, Portugal. · Alfred E. Mann Department of Biomedical Engineering, University of Southern California, 1042 Downey Way, Denney Research Center (DRB) 140, Los Angeles, CA 90089-1111, USA.
Key points
From the paper's conclusion- This study investigates the electrochemical properties of polymer-based microelectrode arrays (pMEAs) and their performance in measuring oxygen (O2) and hydrogen peroxide (H2O2).
Abstract
This study investigates the electrochemical properties of polymer-based microelectrode arrays (pMEAs) and their performance in measuring oxygen (O2) and hydrogen peroxide (H2O2). Morphological characterization by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS) and X-ray diffraction (XRD) revealed a uniform, fine-grained platinum surface with nanoscale roughness, consistent with the Ti/Pt/Au/Pt multilayer stack architecture. The electrochemical behavior of the pMEAs was assessed using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS), which demonstrated favorable responses for both O2 reduction and H2O2 oxidation, together with low impedance (41.1 kΩ at 1 kHz). For O2 detection, amperometric measurements at -0.6 V vs. Ag/AgCl indicated a sensitivity of -0.25 ± 0.04 nA μM-1 and a detection limit of 5.4 ± 1.4 nM. For H2O2 detection, application of +0.7 V vs. Ag/AgCl resulted in a sensitivity of 88.13 ± 7.61 nA mM-1 and a detection limit of 41.9 ± 5.6 nM. Selectivity evaluation showed effective interferent exclusion following m-phenylenediamine electrodeposition, without compromising analytical performance. Overall, these findings indicate the suitability of pMEAs for real-time, in vivo monitoring of O2 and H2O2 in brain tissue with high spatial and temporal resolution, supporting applications in oxidative stress research and neurometabolic sensing.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Microelectrode Arrays in Electroanalytical Chemistry: A Critical Review of Microfabrication, Multiplexed Electroanalysis, Current Analytical Challenges, and Future Intelligent Analytical Platforms.Critical reviews in analytical chemistry · 2026
- Flexible Nano-Platinum Microelectrode Arrays for Sensitive and Spatially Resolved Nitric Oxide Monitoring.Biosensors · 2026
- Nanoarchitectural Control of Nickel-Stabilized Prussian Blue Analogues Improves Hydrogen Peroxide Sensing at Microdisc Electrode Arrays.ACS measurement science au · 2026
- In Vivo Ratiometric Electrochemical Detection of Hypochlorous Acid in Living Brains Using a Methylene Blue-Benzoyl-Based MicrosensorAnalytical Chemistry · 2026
- Carboxyl-enriched molecularly imprinted interface with enhanced electrostatic binding for ultrasensitive oxytocin detection in a portable electrochemical platform.Talanta · 2026
- Development of a thiol-ene microfluidic chip for CE-MS of peptides and proteins.Analytical and bioanalytical chemistry · 2026