Microelectrode Arrays in Electroanalytical Chemistry: A Critical Review of Microfabrication, Multiplexed Electroanalysis, Current Analytical Challenges, and Future Intelligent Analytical Platforms.
Hemn A H Barzani, Rebaz Anwar Omer, Yasir Saeed Ismael, Nihayat Omar Ahmad, Ali Sedeeq Noaman, Seerwan Hamadameen Sulaiman
Department of Medical Laboratory Science, College of Health Science, Lebanese French University, Erbil, Iraq. · Department of Chemistry, Faculty of Sciences and Health, Koya University, Koya 44023, Kurdistan Region - F.R. Iraq.
Key points
From the paper's conclusion- The future impact of MEAs will depend on predictive, transferable, and application-ready performance, not increasing device complexity.
Abstract
Microelectrode arrays (MEAs) integrate microscale mass transport, parallel signal acquisition, and miniaturized instrumentation, offering powerful capabilities for multiplexed, spatially resolved, and real-time electroanalysis. Yet their technological advancement has not produced equivalent gains in analytical reliability or translation. This review critically examines how electrochemical theory, microfabrication, array architecture, multiplexing, system integration, and validation collectively govern MEA performance and technology readiness. MEAs enable rapid responses, low capacitive currents, high-throughput measurements, and multianalyte detection. However, these benefits are frequently compromised by diffusion-field overlap, electrode cross-talk, nonuniform current distribution, fabrication variability, biofouling, matrix interference, signal drift, and unstable calibration. The literature remains dominated by sensitivity and detection-limit claims, whereas accuracy, long-term stability, device-to-device reproducibility, interlaboratory transferability, and scalable manufacturing are insufficiently demonstrated. This review therefore reframes the central barrier to MEA adoption as a measurement-science problem rather than merely a fabrication challenge. Progress requires standardized validation, reproducible manufacturing, self-calibrating arrays, coupled Multiphysics models, and interpretable artificial intelligence. The future impact of MEAs will depend on predictive, transferable, and application-ready performance, not increasing device complexity.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Review and Analysis of Electrochemical Instrumentation Design for Continuous Multi-Analyte Microfluidic Sensor Arrays.Sensors (Basel, Switzerland) · 2026
- Materials and microsystems for stable and high-efficiency brain-computer interfaces in signal recordingnpj Biosensing · 2026
- ALI MEA60: A porous thin-film microelectrode array for air-liquid interface electrophysiology of 3D excitable tissuesbioRxiv · 2026
- Three-dimensional microelectrode arrays for in vitro neuronal network models: structural designs, manufacturing approaches, and future perspectives.Biomedical engineering letters · 2026
- Advances in flexible high-density microelectrode arrays for brain-computer interfacesBiosensors and Bioelectronics · 2025
- Inkjet-Printed Rough Gold Microelectrode Arrays on Flexible Substrates for Neural Recording and Electrical StimulationACS Applied Materials & Interfaces · 2026