Development of a thiol-ene microfluidic chip for CE-MS of peptides and proteins.
Omid Rouhi, Jordan T Aerts, Kamille C Staack, Delaram R Mikalsen, Stephan S Keller, Mohammad Ramezannezhad, Nickolaj J Petersen, Jörg P Kutter,
Protein Analysis Group, Department of Pharmacy, University of Copenhagen, 2100, Copenhagen Ø, Denmark. · National Centre for Nano Fabrication and Characterization, DTU Nanolab, Technical University of Denmark, 2800 Kgs., Lyngby, Denmark.
Key points
From the paper's conclusion- These results highlight the potential of thiol-ene-based MCE-MS as a versatile platform for peptide and protein analysis.
Abstract
Microfluidic capillary electrophoresis coupled with mass spectrometry (MCE-MS) has emerged as a promising platform for miniaturizing biomolecular analysis due to its low sample consumption, rapid separations, and potential for integration of multiple analytical functions on a single device. However, peptide and protein analysis with MCE-MS devices can be limited by electrospray ionization stability and surface adsorption. Here, we have developed a thiol-ene-based MCE device with an integrated electrospray emitter, fabricated using a double-replication molding approach. We improved the performance of the MCE-MS microchip by optimizing electrospray ionization stability and systematically evaluating surface modification strategies to minimize non-specific adsorption and improve separation repeatability. Different MCE channel surface coatings, including linear polyacrylamide and poly(ethylene glycol) methyl ether methacrylate (PEGMA), were investigated for their influence on peptide separations. Both coatings improved separation performance compared to unmodified devices, providing enhanced migration repeatability and reduced non-specific adsorption. PEGMA coatings provided the most balanced overall performance, combining comprehensive analyte compatibility with repeatable migration time and improved peak symmetry with narrower peak width. The optimized coated microchip was utilized for peptide mapping MCE-MS/MS analysis of pepsin-digested hemoglobin. PEGMA-coated chips enabled peptide identification within a separation window of approximately 60 s, achieving sequence coverages of 92.2% and 78.8% for the α- and β-chains, respectively. In addition, intact protein separations of insulin, β-lactoglobulin, and tropomyosin were demonstrated under acidic MCE-MS conditions, with repeatable migration times. These results highlight the potential of thiol-ene-based MCE-MS as a versatile platform for peptide and protein analysis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Novel Tape-Based Microfluidic Chip for Surface Mass Spectrometry Analysis of Biomaterials.Analytical chemistry · 2026
- Automated online microdialysis coupled with capillary electrophoresis via a three-layer PDMS microchip cast in 3D-printed moulds for rapid profiling of free amino acids in milk.Talanta · 2026
- Thiol-Ene Click-Derived Porous-Layer Open-Tubular Column for Online Purification and Multiplex LC-MS/MS Analysis of Neurotransmitters.Analytical chemistry · 2026
- Electrokinetic Enrichment and Purification of Proteins and Anions from High-salt Samples on Liquid Plasticine-Based Open Chip.Analytical chemistry · 2026
- A Modular Chip-Based Interface for Sheathless Capillary Electrophoresis-Mass Spectrometry.Analytical chemistry · 2026
- Expanding the capabilities of capillary electrophoresis for determining protein-DNA binding affinities: physiological conditions and mPEG-silane coating for sticky proteins.Analytical biochemistry · 2026