N-Dodecyl-β-D-Maltoside Replaces Polyethylene Glycol in Reducing Peptide Losses in Autosampler Vials.
Petr Gintar, Ondřej Bucek, David Potěšil, Zbyněk Zdráhal
Mendel Centre for Plant Genomics and Proteomics, Central European Institute of Technology, Masaryk University, Kamenice 5, 625 00 Brno, Czech Republic.
Key points
From the paper's conclusion- Here, we focused on minimizing peptide loss during their transfer and storage in autosampler vials prior to analysis.
Abstract
Background: Sample loss during preparation is one of the issues in unveiling the complexity of the proteome. Here, we focused on minimizing peptide loss during their transfer and storage in autosampler vials prior to analysis. Methods: We used commercially available autosampler TPX vials and HeLa digest. Samples were acidified by formic acid, trifluoracetic acid or their combination and supplemented by polyethylene glycol (PEG, our commonly used additive), n-dodecyl-β-D-maltoside (DDM) or no additive at all. For each injection, 10 ng of peptides was administered at a volume of 10 µL; all samples were analyzed by LC-MS/MS. Results: The DDM-containing samples were able to minimize peptide losses. The addition of DDM outperformed the PEG in observed parameters such as the number of identified peptides throughout the LC gradient or the reduction in losses of high-mass peptides. DDM minimizes peptide losses in samples stored in the autosampler vials for at least seventy-two hours. Conclusions: Under the given experimental conditions, the addition of DDM is capable of replacing PEG and can be used to minimize peptide losses in autosampler vials. The use of DDM is therefore particularly advantageous for those types of samples where DDM cannot be used in the earlier stages of the sample preparation procedure.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Improved Peptide Recovery in Low-Input MS-Based Proteomics Using High-Recovery StageTip Desalting and Nonionic Detergent-Assisted Reconstitution.Electrophoresis · 2026
- MS3 acquisition and μ-SPE cleanup enable sensitive quantification of PPG1000 in zebrafish tissues: systematic comparison with MRM and in-source CID strategies.The Analyst · 2026
- Environmentally Friendly LC-MS/MS Method for the Determination of Etrasimod in Human Plasma via Advanced Phospholipid Matrix Removal.Pharmaceuticals (Basel, Switzerland) · 2026
- Surface-modified liposomes with polyvinyl alcohol derivatives improve mucus penetration and oral absorption: A potential alternative to polyethylene glycol.European journal of pharmaceutics and biopharmaceutics : official journal of Arbeitsgemeinschaft fur Pharmazeutische Verfahrenstechnik e.V · 2026
- Physicochemical Characterization of Liposomal Bilayer Models Loaded with Trans-4-(4'-hydroxy-3'-methoxyphenyl)-5-(1-iodoethyl)dihydrofuran-2-one.Molecules (Basel, Switzerland) · 2026
- Quantitative analysis of free polyethylene glycols in PEGylated peptides using reverse-phase high-performance liquid chromatography and charged aerosol detection.PloS one · 2026