The Analyst

MS3 acquisition and μ-SPE cleanup enable sensitive quantification of PPG1000 in zebrafish tissues: systematic comparison with MRM and in-source CID strategies.

Jiarui Zhang, Zichang Tian, Jinqing Wu, Jiale Liu, Xinyue Zhou, Yue Deng, Shuang Feng, Jing Peng,

Central Hospital of Dalian University of Technology, Dalian University of Technology, Dalian, Liaoning 116023, P.R. China. leiyin@dlut.edu.cn. · Leicester International Institute, Dalian University of Technology, Panjin, P.R. China.

Preclinical

Key points

From the paper's conclusion
  • This work provides the first systematic comparison of MRM, MS3, and in-source CID for PPG quantification, establishing a sensitive analytical platform with complementary greenness and practical applicability assessments using AGREE, AGSA, CACI, and GEMAM, for polymer bioanalysis in complex matrices.

Abstract

Polypropylene glycol 1000 (PPG1000) is a hydrophilic polymer widely used in pharmaceuticals and industry, but quantifying it in complex biological samples remains challenging. This study develops and validates a sensitive UPLC-MS/MS method for PPG1000 measurement in zebrafish tissues. The method combines micro-solid-phase extraction (μ-SPE) cleanup with a 2.5 min chromatographic run and MS3 detection for PPG1000-equivalent quantification in zebrafish tissues. We systematically compared three mass spectrometric acquisition modes: multiple reaction monitoring (MRM), MS3, and in-source collision-induced dissociation (CID). The ammonium adduct [M + NH4]+ of the 15-mer oligomer (m/z 906.6) served as the precursor ion. MS3 using a linear ion trap (m/z 906.6 → 175.1 → 117.1) delivered the highest signal intensity (3.6 × 106 cps), approximately 3.3-fold and 40-fold higher than MRM and CID, respectively. Integrating μ-SPE further improved method performance over conventional protein precipitation. The method showed excellent linearity (100 to 10 000 ng mL-1, r > 0.997) and was applied to zebrafish tissue distribution after aqueous exposure to 200 μg mL-1 PPG1000. All three tissues (gill, liver, and brain) exhibited increasing concentrations from 2 to 4 h, with the gill showing the highest accumulation. Detectable brain levels suggest partial blood-brain barrier penetration. This work provides the first systematic comparison of MRM, MS3, and in-source CID for PPG quantification, establishing a sensitive analytical platform with complementary greenness and practical applicability assessments using AGREE, AGSA, CACI, and GEMAM, for polymer bioanalysis in complex matrices.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers