Effect of different splinting configurations on the accuracy of complete-arch digital implant impressions: An in vitro study.
Simge Öner-Gedik, Helin Yolcu, Pınar Türkoğlu, Ali Murat Kökat
Department of Prosthodontics, Faculty of Dentistry, Istanbul Aydın University, Istanbul, Turkey.
Key points
From the paper's conclusion- The effect of splinting on scanning accuracy was found to be parameter-dependent; G5 was superior in surface RMS and angular deviation, yet no configuration achieved consistent superiority across all parameters. The anterior-premolar region was identified as the highest-risk area for accuracy across all configurations, exhibiting the greatest angular deviation values.
Abstract
BACKGROUND: This in vitro study aimed to investigate the effect of different splinting configurations on the accuracy of digital impressions in fully edentulous arches. MATERIALS AND METHODS: Five configurations were tested on an edentulous maxillary phantom model containing six parallel implant analogs: G1: Non-splinted control, G2: Bilateral posterior splint, G3: Anterior splinted/posterior unsplinted, G4: Segmental independent splinting, and G5: Cross-arch. Ten scans were obtained per group; reference data were acquired using a high-accuracy industrial scanner (Solutionix C500). Point-based RMS (Root Mean Square), surface RMS, and angular deviation (ΔAngle) were calculated using Geomagic Control X. ART ANOVA and one-way ANOVA with Bonferroni-corrected post-hoc tests were applied (α=0.05). RESULTS: Significant differences among groups were detected for all parameters (p<0.001). In surface RMS, G5 exhibited the lowest deviation (0.62 ± 0.15 mm) and G2 the highest (1.27 ± 0.10 mm) (ηp2=0.793). In point-based RMS, G4 showed significantly higher deviation compared to G2, G3, and G5 (0.05 vs. 0.02-0.04mm). Regarding angular deviation, G2 showed the highest and G5 the lowest values (0.26° vs. 0.16°); the anterior and premolar regions demonstrated significantly higher angular deviation than the molar region (0.29-0.34° vs. 0.14°). CONCLUSIONS: The effect of splinting on scanning accuracy was found to be parameter-dependent; G5 was superior in surface RMS and angular deviation, yet no configuration achieved consistent superiority across all parameters. The anterior-premolar region was identified as the highest-risk area for accuracy across all configurations, exhibiting the greatest angular deviation values.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Influence of splinted vs. non-splinted scan bodies on digital impression accuracy in all-on-four implant rehabilitation: a comparison with conventional open-tray impressions.BMC oral health · 2026
- Evaluation of four digital methods in capturing complete-arch implant positions: Direct scanning, splinted scan bodies, three-dimensional-printed scan aids, and intraoral photogrammetry.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2026
- Effect of Scan Body Splinting on Geometric Scan-Body Measurements in Complete-Arch Digital Implant Impressions: An In Vitro StudyProsthesis · 2026
- Effect of Non-Splinting Techniques and Non-Calibrated Implant Scan Body Systems on the Accuracy of Complete-Arch Implant Scans: A Comparative Clinical Study.Clinical oral implants research · 2026
- Clinical Accuracy of Complete Arch Implant Scans Recorded by Using a Customized Metallic Ring-Based Calibrated Framework: An In Vivo Study.Clinical oral implants research · 2026
- Influence of arch form on the accuracy of digital workflow in all-on-four implant rehabilitation cases (an in vitro study).BMC oral health · 2026