Influence of Scan Path and Operator Experience on the Trueness of Extraoral Complete Denture Digitization with an Intraoral Scanner: An Exploratory In Vitro Study
Kanako Shibuya, Tomoko Mukai, Kunihito Yamane, Ryo Sugiki, Tomohiro Tabata, Mana Hirayama, Masataka Watanabe, Junichi Furuya
Key points
From the paper's conclusion- This exploratory in vitro study investigated the effects of scan path and operator IOS experience on the trueness of extraoral scanning of complete dentures.
Abstract
Background/Objectives: Previous studies on the digitization of complete dentures with intraoral scanners (IOSs) have reported inconsistent effects of scan path, and whether these effects depend on operator experience remains unclear. This exploratory in vitro study investigated the effects of scan path and operator IOS experience on the trueness of extraoral scanning of complete dentures. Methods: One maxillary and one mandibular complete denture were scanned with a TRIOS 5 IOS using four scan paths: TRIOS denture, TRIOS dentate, rolling, and BOPLM (buccal–occlusal–palatal/lingual–mucosal) methods. Two experienced and two novice dentists repeated each scan path 10 times per arch. Root mean square (RMS) values relative to reference data obtained with a noncontact three-dimensional scanner (FLARE Pro 16M) were analyzed using linear mixed models with operator as a random effect. Results: In the maxilla, the experience group × scan path interaction was significant (p = 0.034): among novice operators, the rolling method yielded smaller RMS values than the BOPLM method (mean difference = −0.0170 mm, p = 0.001), whereas scan paths did not differ among experienced operators (p = 0.114). No significant effects were found in the mandible. Scanning time did not differ among scan paths. Conclusions: Among novice operators, the rolling method showed higher trueness than the BOPLM method for maxillary dentures. The effect of scan path may depend on operator experience; however, this exploratory finding requires confirmation with a larger number of operators.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Accuracy comparisons of intraoral scanning, stereophotogrammetry, and reverse scanning techniques.The Journal of prosthetic dentistry · 2026
- Trueness and precision of 5 intraoral scanners under different conditions in arches: A 3D comparative in vitro analysis.Dental and medical problems · 2026
- Evaluation of the Influence of Scanning Pattern and Scanning Technology on the Trueness and Precision of the Denture Reference TechniqueJournal of Esthetic and Restorative Dentistry · 2026
- In Vivo Comparison of the Trueness of Conventional and Digital Interocclusal Registration.Bioengineering (Basel, Switzerland) · 2026
- Scanner-Dependent Influence of Palatal Surface Acquisition on Trueness, Precision and Transverse Arch Reproduction During Maxillary Complete-Arch Intraoral Scanning.Journal of dentistry · 2026
- Effect of Preparation Design on the Trueness and Precision of Intraoral Scanners: A Comparative Analysis Across Two IOS Systems.Journal of esthetic and restorative dentistry : official publication of the American Academy of Esthetic Dentistry ... [et al.] · 2026