Accuracy comparisons of intraoral scanning, stereophotogrammetry, and reverse scanning techniques.
Berkman Albayrak, İzim Türker Kader, Elif Nur Köroğlu, Alper Aktosun, Murat Kurt
Assistant Professor, Department of Prosthodontics, Bahçeşehir University School of Dental Medicine, Istanbul, Turkey. Electronic address: berkmanalbayrak@gmail.com. · Assistant Professor, Department of Prosthodontics, Bahçeşehir University School of Dental Medicine, Istanbul, Turkey.
Key points
From the paper's conclusion- Reverse scanning demonstrated the highest linear trueness but the lowest angular trueness among the tested techniques. Although all methods showed clinically acceptable linear accuracy, the angular accuracy of reverse scanning exceeded the clinically acceptable threshold, indicating that its clinical applicability may be limited.
Abstract
STATEMENT OF PROBLEM: Evidence regarding the accuracy of reverse scanning, which has been developed as an alternative to intraoral scanning, is lacking. PURPOSE: The purpose of this study was to compare the accuracy of intraoral scanning and reverse scanning methods using a single scanner and a stereophotogrammetry system for complete arch implant recording under in vitro conditions. MATERIAL AND METHODS: A total of 45 recordings were made from an edentulous maxillary definitive cast with 6 multi-unit abutments using 3 different digital recording techniques (intraoral scanning, reverse scanning, and stereophotogrammetry) (n=15). Intraoral and reverse scanning were carried out using an intraoral scanner (Primescan; Dentsply Sirona), while stereophotogrammetry was performed with Oxo Core (Oxo Technology). The definitive cast was also scanned with a desktop optical scanner (inEos X5; Dentsply Sirona) to obtain the reference model. Linear and angular accuracy, comprising trueness and precision, were evaluated using a reverse-engineering software program (Geomagic Control X; 3D Systems). Trueness was calculated as the deviation from the reference model, and precision was defined as the deviation of repeated measurements from the group mean. Linear trueness was analyzed with the Kruskal-Wallis test and Dunn post hoc comparisons, and angular trueness was assessed using Welch ANOVA and Tamhane T2 post hoc testing. Precision was evaluated with the Kruskal-Wallis test. The significance level was set at α=.05. RESULTS: Significant differences were observed for linear trueness (P=.003), with reverse scanning exhibiting the highest trueness (39.1 µm), followed by intraoral scanning (69.7 µm) and stereophotogrammetry (102.8 µm). Angular trueness also differed significantly (P<.001), with intraoral scanning showing the highest trueness (0.12 ±0.07 degrees) and reverse scanning the lowest (0.67 ±0.16 degrees). Precision did not differ significantly for either linear or angular measurements (P=.082 and P=.058, respectively). CONCLUSIONS: Reverse scanning demonstrated the highest linear trueness but the lowest angular trueness among the tested techniques. Although all methods showed clinically acceptable linear accuracy, the angular accuracy of reverse scanning exceeded the clinically acceptable threshold, indicating that its clinical applicability may be limited.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Accuracy of complete-arch implant positions recorded by analog impressions, intraoral scanning, and extraoral and intraoral photogrammetry.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2026
- Accuracy of complete-arch implant impressions obtained with intraoral scanning, calibrated intraoral scan protocol, extraoral and intraoral photogrammetry, and conventional impression techniques: An in vitro study.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2026
- Influence of an indexing component and intraoral scanner type on the accuracy of reverse scan body digital implant scans.The Journal of prosthetic dentistry · 2026
- Comparative trueness of complete-arch implant position acquisition using auxiliary geometric device-aided and noncalibrated scanbody-based intraoral scanning versus smartphone-based and dedicated extraoral photogrammetry.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2026
- Relative accuracy of intraoral photogrammetry and intraoral scanning with conventional scan-body for full-arch implants.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2026
- Trueness of extraoral photogrammetry, intraoral photogrammetry and direct intraoral scanning in the full-arch digital implant impression: a comparative in vitro studyJournal of Dentistry · 2025