Scanner-Dependent Influence of Palatal Surface Acquisition on Trueness, Precision and Transverse Arch Reproduction During Maxillary Complete-Arch Intraoral Scanning.
Barbara Pamies-Jordana, Ana Lucia Rollano-Calcina, Mitchel Chavez-Gatty, Ignacio Rovira-Torres, Francesc Masip-Madrid, Oscar Figueras-Alvarez
Department of Restorative Dentistry, School of Dentistry, Universitat Internacional de Catalunya, Barcelona, Spain. · Technician in Dental Prosthesis, Familydent Dental Laboratory, Blanes, Spain.
Key points
From the paper's conclusion- Palatal acquisition improved complete-arch scanning with all three scanners, but through different components of accuracy: trueness and transverse accuracy with Aoralscan Elite, repeatability with TRIOS 4 and Primescan.
Abstract
OBJECTIVE: To determine whether palatal vault acquisition affects trueness, precision and transverse arch reproduction in maxillary complete-arch intraoral scanning and whether this is scanner-dependent. METHODS: A fully dentate maxillary typodont was digitized with a desktop reference scanner (3Shape E4). Aoralscan Elite, TRIOS 4 and Primescan each acquired ten scans with and ten without the palate (60 scans). Regions of interest were segmented once on the reference and transferred to every scan. Alignment used only dental surfaces. Trueness was the global and regional root mean square (RMS) deviation from the reference. Precision was the RMS deviation for all 45 test-test pairs per group (270 comparisons). Four arch widths were measured between buccal landmarks. Trueness and widths were analyzed using the aligned rank transform, precision using a linear mixed model. RESULTS: Scanner was the dominant factor for trueness (global RMS F=49.78, p<0.001). Palatal acquisition improved global (F=18.68, p<0.001) and posterior trueness, but not anterior. The scanner-by-palate interaction was significant (F=3.92, p=0.026). Only Aoralscan Elite improved significantly (global median 0.0440 vs 0.0474 mm, Holm p<0.001). Palatal acquisition strongly affected precision (F=33.02, p<0.001). Omitting the palate increased interscan deviation 1.74-fold for TRIOS 4 and 1.68-fold for Primescan (both p<0.001), but not for Aoralscan Elite. All scanners overestimated arch width on average, with greater errors posteriorly. Palatal acquisition reduced errors at both molar widths (p=0.002; p=0.004). CONCLUSIONS: Palatal acquisition improved complete-arch scanning with all three scanners, but through different components of accuracy: trueness and transverse accuracy with Aoralscan Elite, repeatability with TRIOS 4 and Primescan. CLINICAL SIGNIFICANCE: Scanning the palate is a brief additional step that improved complete-arch performance in all three scanners tested. It improved agreement with the reference for one scanner and repeatability for the other two. Because every scanner widened the arch, increasingly toward the molars, including the palate is a reasonable precaution for long-span maxillary restorations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of scan calibrator morphologies on the accuracy of calibrated complete-arch implant intraoral scans: an in vitro study.Journal of dentistry · 2026
- Effect of Preparation Design on the Trueness and Precision of Intraoral Scanners: A Comparative Analysis Across Two IOS Systems.Journal of esthetic and restorative dentistry : official publication of the American Academy of Esthetic Dentistry ... [et al.] · 2026
- The effect of intraoral scanner tip size and scanning strategy on the digital impression trueness of full-arch implant-supported prostheses: an in vitro study.The journal of advanced prosthodontics · 2026
- Evaluation and comparison of the scanning accuracy of three intraoral scanners for single crown, three-unit, and cross-arch fixed partial denture by three-dimensional digital superimposition technique and measurement of vertical marginal fit of three-dimensional-printed resin retainers: An in vitro study.Journal of Indian Prosthodontic Society · 2026
- Effect of a stackable scanning guide, intraoral scanner type, and operator on the accuracy of maxillary full-arch implant scans: An in vitro studyJournal of Dentistry · 2026
- Influence of implant scan body material and intraoral scanner system on the accuracy of three-unit implant scans.The Journal of prosthetic dentistry · 2026