Virtual-Node-Enhanced Mirror-Equivalent Energy Framework for Online Transient Stability Assessment of EHV Transmission Lines
Chao Huo, Xiaojing Hu, Jiacheng Liu, Dingyang Suo, Jun Liu
Key points
From the paper's conclusion- These results demonstrate improved CoO localization accuracy and more reliable stability assessment under the tested conditions.
Abstract
Online transient stability assessment (TSA) is essential for the secure operation of long-distance extra-high-voltage (EHV) transmission lines. Mirror-equivalent energy (MEE) methods depend on accurate center-of-oscillation (CoO) localization, but conventional two-terminal frequency interpolation may inadequately represent internal frequency variations in long EHV lines. Measurement noise can further affect weighted least-squares (WLS) state estimates and subsequent energy assessment. This paper proposes a virtual-node-enhanced MEE framework that reconstructs internal frequency responses using extended Kalman filter (EKF)-estimated generator states and a multi-section π-equivalent transmission-line model. The CoO is located through linear-regression analysis and used to construct the mirror-equivalent system and calculate the MEE index. The framework is evaluated using a PSS/E model of a 750 kV, 300 km double-circuit transmission line in the Northwest China Power Grid. In the representative stable and unstable cases of the studied system, virtual-node reconstruction reduces the absolute CoO location errors from 5.236 to 3.281 km and from 65.021 to 0.349 km, respectively, compared with two-terminal interpolation. In 200 paired Monte Carlo trials at SNRs of 40 and 30 dB, the EKF-based method produces smaller mean CoO location errors and no incorrect stability decisions, whereas the WLS-based method produces seven incorrect decisions. Additional simulations evaluate the framework under different pre-fault transfer powers, fault locations, fault types, and clearing times. These results demonstrate improved CoO localization accuracy and more reliable stability assessment under the tested conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Counterfactual Screening of Rare Secondary Overloads in Power Grids with a Stochastic Surrogate for Electromagnetic Transient SimulationsarXiv · 2026
- A Three-Stage Methodology for Accelerated Monte Carlo Assessment of the Lightning Performance of Large Branched Distribution NetworksEnergies · 2026
- Enhancing Transient Stability of VSG-Controlled Converters Under Grid Frequency DisturbancesarXiv · 2026
- Online Evaluation of Measurement Uncertainty in Sensor Networks: A Case Study on Voltage TransformersIEEE Transactions on Industrial Informatics · 2026
- Phase-Coordinate Modeling of Electromagnetic Transients for Fault Analysis in Distribution NetworksElectronics · 2026
- Fault identification and localization in transmission lines using an IVY-optimized generalized additive modelScientific Reports · 2026