Scientific Reports

Fault identification and localization in transmission lines using an IVY-optimized generalized additive model

Rui Qiao, Wenhao Zhou, Wei Dai, Tonghua Wu, Feng Liu, Jun Chen

Key points

From the paper's conclusion
  • Stratified five-fold out-of-fold evaluation further yields an identification accuracy of 99.22% and a macro-averaged F1-score of 0.992, while the localization task obtains a mean MAE of 7.08 km and a mean $$R^2$$ of 0.9520.

Abstract

Accurate fault-type identification and fault-distance estimation are essential for the reliable operation of transmission lines, yet their simultaneous realization remains challenging under nonlinear transient responses and limited labeled data. This study proposes an IVY-optimized generalized additive model (IVY-GAM) framework that combines physically guided feature construction, interpretable nonlinear modeling, and adaptive hyperparameter optimization. A 200 km two-terminal transmission-line model is established in MATLAB/Simulink to generate 385 fault samples covering 11 fault categories. Twelve features are constructed from phase-mode transformation, db4 wavelet decomposition, transient modulus maxima, three-phase voltage statistics, and double-ended wavefront-arrival indices. IVY is then used to optimize the key GAM parameters for fault identification and localization. Under a fixed train–validation–test partition, IVY-GAM achieves an identification accuracy of 99.987% and a localization $$R^2$$ of 0.99674, with an MAE of 3.16 km, an RMSE of 3.91 km, and a maximum error of 11.84 km. Stratified five-fold out-of-fold evaluation further yields an identification accuracy of 99.22% and a macro-averaged F1-score of 0.992, while the localization task obtains a mean MAE of 7.08 km and a mean $$R^2$$ of 0.9520. Feature-group ablation, permutation importance, and GAM main-effect analyses show that three-phase voltage means primarily support fault-type discrimination, whereas double-ended arrival indices dominate distance estimation and modal maxima provide complementary information. The proposed framework therefore offers a balanced solution for accurate, interpretable, and computationally efficient transmission-line fault diagnosis.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Fault identification and localization in transmission lines using an IVY-optimized generalized additive model — Science Skim